Power and

Utility

Requirements

These loads are passive devices that are self contained and

do not require any external source of power or utility to

function other than the RF input power.

Environmental

Requirements

These loads should be operated in a dust and vibration-free

environment. The ambient temperature range should re-

main between -40°C and +45°C (-40°F and +113°F) for

proper operation. Allow at least six inches of clearance

around the units to permit an unimpeded access of convec-

tion air currents for adequate heat dissipation.

Items

Furnished

Series 8000 Loads are normally equipped with a

Quick-Change “QC” connector for convenient and easy inter-

change with other AN type “QC” connectors. Model 8431 has

a Small Quick-Change “SQC” connector which is not inter-

changeable with “QC” types. Consult the Specification

Sheet, Page 3, for the connector type normally supplied with

each load.

Items Required

The only other item required is a mating connector on the

coaxial transmission line to which the load will be con-

nected.

Tools and Test

Equipment

Only a screwdriver will be necessary for changing the “QC”

connectors. None of these loads are subject to any further

disassembly. An ohmmeter or resistance bridge with an ac-

curacy of one percent or better at 50 ohms is useful for

checking the resistance value of the RF section assembly.