Bendix Commercial Vehicle Systems ACom Diagnostics V.6.7 User Manual
Page 23
23
Customize
The Customize screen allows the technician to customize some of the features in the installation test.
Warning: The tests conducted must match the features of the vehicle being tested. With each
vehicle, it is important to confirm that the correct sets of features are being verified. Typically the
Bendix
®
ACom
®
Diagnostics software will save the features used on the previous test, so if the
software was used on a vehicle with different features during its last use, the customized features
must be re-assessed and changed to match the new vehicle.
To complete any necessary changes, simply click in the box next to a desired test name — a check mark
will appear — to request that the test be performed. Similarly, you may uncheck boxes to skip those tests.
Mandatory tests are displayed on the screen in gray, optional tests appear in black.
You may use the screen to:
• Re-arrange the order of the tests
• Save a report in TXT or HTML format
• Save a report using the VIN as the filename
• Create a folder in which to save the report (the program will prompt to ask for a folder and file name)
• Select to show wheel speeds in either MPH or RPM
• Select if you wish the test sequence to stop if the previous test failed
• Select if the technician needs to confirm if the service brake is applied during the modulator test
Figure 27
Control Buttons for Customize
• The
OK
button is used to accept changes
• The
Cancel
button is used to cancel (not accept) changes
• The
Up
button moves highlighted test up the list
• The
Down
button moves highlighted test down the list
If there are any active Diagnostic Trouble Codes (DTCs) on the Electronic Control Unit (ECU), the
installation will not run, and the technician will be notified by a message. Active DTCs must be corrected