2. Operation of the Bally Speed-Lok:
A. Before attempting to erect panels, familiarize yourself with the operation of the locks Figures 2, 3, and 4. On Bally panels, locks
will always be on the left turning in clockwise rotation. If for any reason you have to unlock a panel, refer to Section B below.
B. Replacing broken or stripped locks
1. The panel contained the lock must be slid away from adjacent panels in order to obtain adequate working space. First check for
any obstructions (dirt, foam, etc) once you have unlocked a panel reset the cam stop by turning the lock fully back to its original
position. If the hook is broken or stripped replacements can be found in Miscellaneous Parts Box#1.
2. Position the lock wrench on the hex rod and turn clock-wise until the locking arm protrudes.
3. Place your hand near the bend in the wrench and use a lift-up motion. This will produce a clamping action on the hex rod. While
doing this, pull forward until the rod is free of the panel. The locking arm will then drop free. See Figure 2.
4. Hold the new locking arm in position. Make sure the hook of the arm faces in the proper direction. See Figure 3.
5. Insert the new hex rod into the lock hole. Care must be taken to insert the notched end of the rod. The end to be inserted has a
notch located 1” from the end. This notch acts as a stop so the rod will not be inserted too far.
6. Align the hex rod with the hex hold of the locking arm; gently tap it until the notch stops against the locking arm.
7. Replace and refasten the panel in its original position.
Always refer to your
Plan View when installing your Bally Walk-In Cooler or Freezer.
Figure 3
Figure 1
Figure 2