DOWNFLOW SUBBASE

LOCATING

TAB

LOCATING

TAB

1

2

3

4

4

3

2

1

B

D

C

A

1

1

/

4-IN. TYP

PLENUM
OPENING

FACTORY-SUPPLIED

FIELD-INSTALLED

INSULATION

Assembled

Disassembled

A97427

A88207

DIMENSIONS (IN. / MM)

FURNACE

CASING WIDTH

FURNACE IN DOWNFLOW

APPLICATION

PLENUM OPENING*

FLOOR OPENING

HOLE NO. FOR

WIDTH

ADJUSTMENT

A

B

C

D

17---1/2 (444.5)

Furnace with or without Cased Coil

Assembly or Coil Box

15---1/8

(384.2)

19 (482.6)

16---3/4

(425.5)

20---3/8

(517.5)

3

21 (533.4)

Furnace with or without Cased Coil

Assembly or Coil Box

18---5/8

(396.4)

19 (482.6)

20---1/4

(514.4)

20---3/8

(517.5)

2

24---1/2 (622.3)

Furnace with or without Cased Coil

Assembly or Coil Box

22---1/8

(562.0)

19 (482.6)

23---3/4

(603.3)

20---3/8

(517.5)

1

*The plenum should be constructed 1/4---in. (6 mm) smaller in width and depth than the plenum dimensions shown above.

Concentric Vent Kit

A93086

A concentric vent kit allows vent and combustion--air pipes to
terminate through a single exit in a roof or side wall. One pipe

runs inside the other allowing venting through the inner pipe and
combustion air to be drawn in through the outer pipe.

Downflow Subbase

A88202

One base fits all furnace sizes. The base is designed to be installed
between the furnace and a combustible floor when no coil box is

used or when a coil box other than a Carrier cased coil is used. It is
CSA design certified for use with Carrier branded furnaces when

installed in downflow applications.

915SA