beautypg.com

Specifications, General, Input – Vicor Javelin III User Manual

Page 10: Output

background image

Javelin III Power Supply Operator’s Manual

Rev. 05/11/2012 Mission Power Solutions (760) 631-6846 [email protected] Pg. 10

Specifications

(Typical at 25C, nominal line and 75% load, unless otherwise specified)

General

Number of Outputs

1

Efficiency

75%

Safety Approvals

N/A

MIL-STD’s

461E; 704E; 810E; 1399

Maximum Output Power

2400W, 115 VAC

3600W, 230 VAC

5400W, 230 VAC (Selected Output Voltages)

Input

Input

85-254 VAC, 47-500Hz

100-380 VDC

Line Regulation

 0.2% from 10% load to full load

Inrush Current

90A rms. max. @ 115 VAC
180A rms. max. @ 230 VAC
60A rms. Max @ 230 VAC, three phase

Ride-Through Time

20 ms at 3600W load

Conducted EMI

FCC Class A, EN 55022 Class B

MIL-STD-461E

Power Factor

.99 (115 VAC 2400W load)

.95 (230 VAC 3600W load)

Transient Surge

IEC 801-5 level 3

(Common Mode & Normal Mode)

Dielectric Withstand

Primary to Chassis GND = 2121 VDC

Primary to Secondary = 4242 VDC

Secondary to Chassis GND = 50 VDC

Output

Parameter

MIN.

TYP.

MAX.

UNITS

NOTES

Setpoint Accuracy

0.5

1

% of V

NOM

Load/Line Regulation

0.02

0.2

% of V

NOM

0% to 100%

Temperature Regulation

0.002

0.005

%C

20 to 100C

Long Term Drift

0.02

%1K hours

Output Ripple – pp:

2V, 3.3V

100

mV

20 MHz bandwidth

5V

2

%

20 MHz bandwidth

12-95V

1

%

20 MHz bandwidth

Trim

N/A

Consult Factory

Total Remote Sense Compensation 0.5

Volts

0.25V max. each leg

OVP Set Point

112

135

% of V

NOM

Recycle power

Current Limit

102

135

% of I max

Automatic restart

Over-Temperature Protection

Varies according to power level