Vicor VIPAC Array Family of DC-DC Converters Up to 750 Watts User Manual

Page 4

background image

6

Mating Connector

Vicor part #

Amp part #

Housing

24795

2-794657-0

Contacts

24796

1-106529-2

Kit

24828

7

Parallel/Redundant Connections

Parallel/Redundant Connections

L

O

A

D

PR bus leads should be connected

to like pin #’s on redundant arrays

when equipped with optional

current share transformer.

*Removable jumpers in J4 are factory installed for local sensing. For remote

sensing the +Sense pins should be tied to the same point on the +Out power

bus; the -Sense pins should be tied to the same point the -Out power bus.

** There should be one master module, this is realized by choosing one

module to be the master and shorting the SC to –S on the other module.

Units configured from the factory as paralled will already have this

configured.

Pin # Conn. Function

Mating Conn.

1

– Vout

J4-1

– Vout

J4-2

– Sense

J4-3

Secondary Control

P/N 16385

J4-4

+ Sense

J4-5

+ Vout

*Removable

Jumper

*Removable

Jumper

Factory Installed

Mini/Maxi LugMate

*

P/N 16385

J4

1

5

1

5

1

5

*

P/N 16385

J4

1

5

#10-32 torque 16 in. lbs.

1

11

20

10

Input Connector
(View looking into J1)

*

P/N 16385

1

5

J4

Pin #

Function

1-4

–Vin

5-7

+Vin

8

NC / PR bus

9

PE protective earth

10

– Remote enable

11-13

–Vin

14-17

+Vin

18

NC / PR bus

19

PE protective earth

20

+ Remote enable

VA-J & VA-K configurations only
(300 & 375 Vin single Maxi &
single Mini)

Pin #

Function

1-3

–Vin

4-6

+Vin

7

NC

8

NC / PR bus

9

PE protective earth

10

– Remote enable

11-13

–Vin

14-16

+Vin

17

NC

18

NC / PR bus

19

PE protective earth

20

+ Remote enable

To disable output(s) apply +5 Vdc

between pins 10 and 20 in the polarity

indicated