Input /output connections – Vicor VIPAC Array Family of DC-DC Converters Up to 750 Watts User Manual
Page 3
Pin #
Function
1-4
–Vin
5-7
+Vin
8
NC / PR bus
9
PE protective earth
10
– Remote enable
11-13
–Vin
14-17
+Vin
18
NC / PR bus
19
PE protective earth
20
+ Remote enable
VA-J & VA-K configurations only
(300 & 375 Vin single Maxi &
single Mini)
Pin #
Function
1-3
–Vin
4-6
+Vin
7
NC
8
NC / PR bus
9
PE protective earth
10
– Remote enable
11-13
–Vin
14-16
+Vin
17
NC
18
NC / PR bus
19
PE protective earth
20
+ Remote enable
4
5
Factory Installed Micro LugMate
1
3
Input /Output Connections
Input /Output Connections
1
11
20
10
Mating Connector
Vicor part #
Amp part #
Housing
24795
2-794657-0
Contacts
24796
1-106529-2
Kit
24828
Input Connector
To disable output(s)
apply +5 Vdc
between pins
10 and 20 in the
polarity indicated
NOTE: Contacts accept #22-#18 Gage Wire.
Solder
Pin #
Pad
Function
1
– Vout
Rd
Trim Down
SC
Secondary Control
Ru
Trim Up
3
+ Vout
Consult design calculator for Rd/Ru trim resistor
values located at vicorpower.com.
Pin # Conn. Function Mating Conn.
1
– Vout
J4-1
– Vout
J4-2
– Sense
J4-3
Secondary Control
P/N 16385
J4-4
+ Sense
J4-5
+ Vout
5
+ Vout
*Removable
Jumper
*Removable
Jumper
#10-32 torque 16 in. lbs.
J4
1
5
Factory Installed
*Removable jumpers in J4 are factory installed for
local sensing. For remote sensing the +Sense pins
should be tied to the same point on the +Out power
bus; the -Sense pins should be tied to the same point
the -Out power bus.
*
P/N 16385
1
5
#4-40 torque 4 in. lbs.
Discrete Output
Parallel Output
Shown with the output(s) of two
modules connected in parallel
using factory installed bus bar.