6 specifications, 1 physical characteristics, 2 electrical characteristics – Ultralife CH0007 User Manual
Page 22: Specifications, Hysical, Haracteristics, Lectrical

CH0007 Operation Manual
Newark, New York | 315-332-7100 | Fax: 315-331-7800
©2010 Ultralife Corporation • www.ultralifecorp.com • All specific subject to change without notice
The information contained herein is for reference only and does not constitute a warrant of performance •
30 SEP 10 UBI-5166 Rev: A
Page 22 of 25
6 SPECIFICATIONS
6.1 Physical Characteristics
Dimension
Measurement
Width
8.4 inches (21.3 cm)
(Including mounting brackets)
Length
27.3 inches (69.3 cm)
Height
14 inches (35.6 cm)
Weight without Cables
and Batteries
36 Lb. (16.3 kg)
Color
Olive Drab Green
Case
CARC coating - MIL-DTL-64159
Display
VFD graphical and LED status displays
Controls
On/Off Toggle Switch, Conditioning Override toggle switch, VFD brightness tog
switch
Typical Charge Time
(UBBL03)
< 2.5 Hours
Mounting Mounting
rails
integrated on back of charger
External
Communication
USB port for software upgrades and remote monitoring
(Additional software and P
required)
Battery Communication
SMBUS V1.1 w/ PEC (Packet Error Protection)
SMBUS Charger Level 3 Compliant
6.2 Electrical Characteristics
Dimension
Measurement
Charger Input Range
21 to 32 volts DC (Low Power Alarm below 22V)
Charger Input Current
40 to 90 Amps (Circuit Breaker Protected at 75A)
Maximum Battery Charge Current
5A
Minimum Battery Charge Current
0.3A
Maximum Charge Voltage
16.8V
Maximum Conditioning Discharge Current
2A
Power Standard
MIL-STD-1275 compliant