Ao l, Performance curves, Low noise option – Thermal Transfer Systems AOL Series User Manual
Page 4

AO
L
www.thermaltransfer.com
262.554.8330
53
A
IR C
O
O
L
E
D
AO
L
600
500
400
300
200
100
0
10
(37.85)
20
(75.71)
30
(113.562)
40
(151.42)
60
(227.12)
80
(302.83)
100
(378.54)
200
(757.08)
400
(1514.16)
300
(1135.62)
Horsepower Removed in Cooler @ 100°F ETD
8.1
6.7
5.4
4.0
2.7
1.3
0
Heat Rejection (KW/°C)
GPM (LPM) Oil Through Cooler
= 5 PSI
= 10 PSI
= 15 PSI
= 20 PSI
= 30 PSI
(0.34 BAR)
(0.69 BAR)
(1.03 BAR)
(1.38 BAR)
(2.75 BAR)
Oil P
Performance Curves
Low Noise Option
H
or
se
po
w
er
R
em
ov
ed
in
C
oo
le
r @ 100°F ETD
Flow Rate GPM (LPM)
AOL-725-LN
AOL-950-LN
AOL-1200-LN
AOL-1600-LN
AOL-400-LN
AOL-2000-LN
AOL-2500-LN
AOL-3000-LN
AOL-3500-LN
600
500
400
300
200
100
0
8.1
6.7
5.4
4.0
2.7
1.3
0
10
(37.85)
20
(75.71)
30
(113.56)
40
(151.42)
60
(227.12)
80
(302.83)
100
(378.54)
200
(757.08)
400
(1514.16)
1000
(3785.40)
300
(1135.62)
H
ea
t R
ej
ec
tio
n
(KW/°C)
= 5 PSI
= 10 PSI
= 15 PSI
= 20 PSI
= 30 PSI
(0.34 BAR)
(0.69 BAR)
(1.03 BAR)
(1.38 BAR)
(2.75 BAR)
Oil P
Available in 60 Hz Nema Frame only.
Note: Derate heat rejection values 15%