Performance curves, 1 oil to water ratio – low water usage, 1 oil to water ratio – medium water usage – Thermal Transfer Systems EC Series User Manual
Page 5

EC
262.554.8330
www.thermaltransfer.com
88
W
A
T
E
R C
O
O
L
E
D
EC
Performance Curves
4:1 Oil to Water Ratio – Low Water Usage
9 10
15
20
25
30
40
50
60 70 80 90 100
150
200
250
8
9
10
15
20
25
30
40
50
60
70
80
90
100
150
200
250
300
400
7
OIL FLOW (GPM)
HORSEPOWER REMOVED IN COOLER
19
15
18
14
13
10
12
11
1
2
3
4
5
6
7
8
9
17
16
OIL P
= 5 PSI
= 10 PSI
= 20 PSI
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
▲
1. EC-1014-7-F
2. EC-1014-4-F
3. EC-1024-6-F
4. EC-1024-4-F
5. EC-1036-6-F
6. EC-1054-7-F
7. EC-1224-12-F
8. EC-1224-6-F
9. EC-1236-9-F
10. EC-1236-6-F
11. EC-1254-9-F
12. EC-1272-9-F
13. EC-1724-6-F
14. EC-1736-9-F
15. EC-1754-14-F
16. EC-1754-9-F
17. EC-1772-12-F
18. EC-1772-9-F
19. EC-1784-14-F
28
28
45
45
66
105
98
98
125
125
155
210
145
201
275
275
330
330
390
32
32
50
50
70
140
105
105
145
145
180
250
175
235
305
305
380
380
450
Weights (lbs)
Model
net
Approx. Shipping
9 10
15
20
25
30
40
50
60 70 80 90 100
150
200
250
8
9
10
15
20
25
30
40
50
60
70
80
90
100
150
200
250
300
400
500
600
OIL FLOW (GPM)
HORSEPOWER REMOVED IN COOLER
OIL P
= 5 PSI
= 10 PSI
= 20 PSI
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
■
▲
▲
▲
▲
▲
▲
▲
▲
▲
19
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
18
1. EC-1014-7-T
2. EC-1014-4-T
3. EC-1024-6-T
4. EC-1024-4-T
5. EC-1036-6-T
6. EC-1054-7-T
7. EC-1224-12-T
8. EC-1224-6-T
9. EC-1236-9-T
10. EC-1236-6-T
11. EC-1254-9-T
12. EC-1272-9-T
13. EC-1724-6-T
14. EC-1736-9-T
15. EC-1754-14-T
16. EC-1754-9-T
17. EC-1772-12-T
18. EC-1772-9-T
19. EC-1784-14-T
28
28
45
45
66
105
98
98
125
125
155
210
145
201
275
275
330
330
390
32
32
50
50
70
140
105
105
145
145
185
250
175
235
305
305
380
380
450
2:1 Oil to Water Ratio – Medium Water Usage
Weights (lbs)
Model
net
Approx. Shipping