The startup screen is not displayed,

and the computer is not recognized by

LinkTheater

Cause (1):

The LAN cable is not connected

Solution (1):

Check that the LAN cable is connected to

both the computer and LinkTheater (push in

the LAN cable until you hear a “click”). After

connecting the LAN, switch the LinkTheater

power off and on again.

Cause (2):

The wrong cable is being used (when

connecting directly to a computer)

Solution (2):

You need to use a crossover cable when

connecting LinkTheater directly to a

computer. Connect with a crossover cable.

After connecting the cable to the LinkTheater

and to your LAN, switch the LinkTheater's

power off and then on again.

Cause (3):

The software that came with LinkTheater has

not been installed

Solution (3):

Insert the CD provided into the computer’s

CD drive, and click [Install PC-P1LAN Utility]

from easy setup.

Cause (4):

The BootServer is not running on your PC

Solution (4):

Check that the BootServer icon

is

displayed in the task tray. If the icon is not

displayed, click [Start]-[(All) Programs]-

[BUFFALO]-[PC-P1LAN]-[PC-P1LAN

BootServer].

Cause (5):

There is a problem with the router or access

point

Solution (5):

If you have tried all of the above solutions

but LinkTheater is still not recognized on

the environment connected to your router or

access point, refer to [Read Me First] and

connect LinkTheater directly to the computer.

Cause (6):

The IP address is wrong

Solution (6):

Refer to “For customers that do not have

a router” (page 12) and check that the

computer IP address and LinkTheater

IP address have the first three groups of

numbers the same, and the last group of

numbers different. For example, if the

LinkTheater IP address is [192.168.11.51],

check that the computer's IP address is

[192.168.11.61] or something similar. Subnet

masks should be the same for both.

Cause (7):

Software that contains a firewall is installed

Solution (7):

If a firewall is enabled, the computer may

not be recognised from LinkTheater. In this

case, you can disable the firewall function

or accept use of UDP ports [59821] [59823]

and TCP ports [8888] [9666] [9667] [58080]

[58001] [59824], or uninstall the software that

has firewall settings. Contact the software

maker for information about firewall settings.

The following is an example of how to

disable a firewall.

[When Trend Micro PC-Cillin 2003 is

installed]

Use the following procedure to disable the

[Personal firewall function].

1. Select [Start] - [(All) Programs] - [Trend

Micro PC-Cillin-2003] - [PC-Cillin-2003

operations].

2. When the [PC-Cillin-2003 operation screen]

starts, click on the [Professional] tab.

3. Click the [Emergency lock] button

displayed on the right side, check that

[Emergency lock is OFF] is displayed, and

click [OK].

4. Check that there is an x mark in the

[Wireless LAN mode] button. If there is no x

mark, click the [Wireless LAN mode] button

to switch the wireless LAN mode OFF.

When these settings are completed, close

the [PC-Cillin 2003 operation window].