Unit will not run (see following page for steps) – TapeTech CFFULL Cont. Flow Full Bundle User Manual

Page 25

background image

Troubleshooting

3A0245A

25

Unit Will Not Run
(See following page for steps)

Turn unit ON.

Error Code
Displayed

See Error Code
section for further
troubleshooting

Connect a test

transducer to the

board. Does the

motor run?

Replace

potentiometer.

See Step 3. Is the

proper reading

present through the

thermal switch

wires?

Replace the

ON/OFF switch.

See step 4. Does

the motor run?

See Step 1. Do

you have over

100 AC volts (200

for 230V units)?

See Step 2. Do

you have over

100 AC volts (200

AC volts for 230V

units?

Repair or

replace

power cord.

If motor is hot, let cool and

retest. If Step 4 still shows

incorrect resistance, replace

motor. The motor has

a defective thermal device.

Replace the

control board.

YES

YES

YES

NO

NO

NO

NO

YES

YES

NO

Replace the

transducer.