TapeTech CFFULL Cont. Flow Full Bundle User Manual
Page 22

Troubleshooting
22
3A0245A
Drywall feed pump does not
run at all
Control is commanding motor to
run but motor shaft does not
rotate. Possibly locked rotor con-
dition, an open connection exists
between motor and control, there is
a problem with motor or control
board, or motor amp draw is
excessive.
6.
Perform Field Short Test: Test at large 4-pin motor
field connector. There should not be continuity from
pin 4, the ground wire, and any of the remaining
3 pins. If motor field connector tests fail,
replace motor.
7.
Check Motor Thermal Switch: Unplug thermal
wires. Set meter to ohms.
Meter should read 6.2k ohms.
Digital display shows E=05
Control board status light
blinks 5 times repeatedly
TYPE OF PROBLEM
WHAT TO CHECK
HOW TO CHECK
-
ti13140a
This manual is related to the following products: