MAINTENANCE

FAN REMOVAL / INSTALLATION

2. Lift fan bracket and fan off pins from base of unit.

6. Reverse steps 2-1.

3. Pull out bracket and fan, disconnect wires. Remove fan (to service or

replace) from bracket by removing three (3) screws as shown below.

Before you begin:
Shut off the gas supply to the unit.
Disconnect all electrical supply to the unit.
Always let the appliance cool to room temperature before servicing.

Note: To access the rear access panel, both the gas and venting (see

vent/fl ue installation in this manual) will need to be disconnected for
proper removal. There is no access to the blower from the front of
this appliance.

4. Position gasket between fan and back access panel as shown below in

Diagram 4. Secure fan and gasket to fan bracket with 3 screws.

Diagram 4

Gasket

5. Connect the wires from the wire harness to the fan terminals (see

Diagram 5a)and connect the other end to the wires of the fan control box
(see Diagram 5b).

See wiring diagram on next in this manual.

Fan Terminals

Fan Control Box

Diagram 5b

Diagram 5a

Diagram 1

1. Remove 9 screws and loosen 5 screws along the bottom to remove fan

access panel -see Diagram 1

= Remove
= Loosen

Pins Diagram 2

Diagram 3

FAN INSTALLATION