beautypg.com

Installation – Regency Liberty L390PB Medium Gas Insert User Manual

Page 18

background image

18

L

390

PB-2 / HZI

390

PB-2 Direct Vent Gas Insert

INSTALLATION

13. Verify that if the conversion is from NG to LPG, the screw must be re-

assembled with the red o-ring visible (Fig. 5).

LPG Configuration

Red o-ring visible

Fig.5

14. Re-assemble the black protection cap (Fig. 6).

15. Reverse steps 5 - 1.

Fig. 6

WARNING!

Also check that the pilot and main

burner injectors are appropriate for

the gas type.

17. Replace yellow "NG" label with red "LPG" label.

18. Check for gas leaks.

19. Adjust aerations settings - see Air Shutter Adjustment section in the manual.

20. Check inlet and outlet pressures.

21. Check operation of fl ame control.

16. Attach the label "This unit has been converted to LPG" near or on top

of the serial # decal.

Fig.2

12. Using the Allen wrench as shown in Fig. 4, rotate the screw clockwise until

snug, do not overtighten.

Fig.4

Fig.3

9. Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the

screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.

10. Check that the screw is clean and if necessary remove any dirt.

11. Flip the screw (Fig. 3).

WARNING!

Do not over tighten the screw.

Recommended to

grip the wrench by the short side.

Fig. 1

8. Remove the black protection cap by hand from the hi-low knob (Fig.1).

Installer Notice:

These instructions must be left

with the appliance

.

This manual is related to the following products: