Installation – Regency Liberty L390PB Medium Gas Insert User Manual
Page 30
30
L
390
PB-2 / HZI
390
PB-2 Direct Vent Gas Insert
INSTALLATION
7
3
6
1
3
2
4
390 Pin Landing
540 Pin Landing
1
4
5
6. Place Log 4, match pin locator on Log 4 with landing pin on Log
1. Angle the longest point on Log 4 is approximately 1/4' from the
outside edge of the burner tray.
7. Place Log 5 across Log 4,match pin locator on Log 5 with landing
pin on Log 4.
Note: there are 2 pin locators on Log 5, lower locator is for 390 units
and the upper locator is for the 540 units.
8. Place Log 6 - rest on Log 3 as shown below.
9. Place Log 7 on the glass as shown below.
10. Place embers and Lava rocks on the glass as shown below.
Note: Properly positioned, Logs 3 & 4 should measure 1/4" from their
longest point to the outside edge of the burner tray.
4
3
1/4"
1/4"
1
2
3
5. Place Log 3, rest on Log 2, match pin locator on Log 2 with landing
pin on Log 1. Angle the longest point on Log 3 is approximately 1/4'
from the outside edge of the burner tray.
11. Reinstall Glass Door.
12. Adjust aeration setting to fully open (manual for detailed instruc-
tions)
Note: Logs to be installed in NG units only.
Line up pin locator and pin, Logs 1,3
Line up pin locator and pin, Logs 1,4
Line up pin locator and pin, Logs 5,4
Position Log 6
Position Log 7
Place Lava Rock and Embers on Glass