INSTALLATION
LEVELLING LEG ADJUSTMENT
The L390PB / HZI390PB inserts are equipped with 2 levelling legs that are accessible while the appliance is in its fi nal installation position. The unit can be
adjusted up to 2" (51mm). The faceplate must not be installed to do this adjustment, if installed, remove faceplate.
Remove left and right side fi ller pieces. The rear levelling bolts are located in the back corners of the fi rebox and can be adjusted using a 7/16" wrench.
Rotate the bolts clockwise to raise the rear of the fi rebox.
When the appliance is in position, adjust the bolts to level the appliance, making sure that the appliance is also level and is sitting on both bolts to prevent
rocking.
Leveling Bolts