Caution Requirements

The top, back and sides of the decorative gas appliance

are defi ned by standoffs. The metal ends of the

standoff may NOT be recessed into combustible

construction.

WARNING

Fire hazard is an extreme risk

if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this decorative gas

appliance be installed only in accordance with these instructions.

MINIMUM CLEARANCES TO COMBUSTIBLES

The clearances listed below are Minimum distances unless otherwise stated:

A major cause of fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
decorative gas appliance be installed only in accordance with these instructions.

PTO28 Clearance Requirements

Clearance:

Dimension

Measured From:

A: Back wall

12" (305mm)

Table Top to back wall

B: Sidewall

12" (305mm)

Table Top to sidewall

C: Ceiling

45" (1143mm)

Table Top to Ceiling

D

1

: Floor

D

2

: Floor

0"

When using supplied leveling legs.

1"(25mm)

Unit Base to Floor

E: Alcove Width

84"(2134mm)

Wall to Wall (Minimum)

F: Alcove Depth

72" (1829mm)

Front to Back Wall (Maximum)

Notes:

0"

No Hearth Required

E

F

Alcove

C

A

B

D