Installation, Minimum clearances to combustibles – Regency Plateau PTO28CIT Outdoor Gas Firetable User Manual
Page 9
Regency PTO28 City Table Outdoor Gas Fireplace
9
INSTALLATION
Caution Requirements
The top, back and sides of the decorative gas appliance
are defi ned by standoffs. The metal ends of the
standoff may NOT be recessed into combustible
construction.
WARNING
Fire hazard is an extreme risk
if these clearances (air space) to combustible materials are not
adhered to. It is of greatest importance that this decorative gas
appliance be installed only in accordance with these instructions.
MINIMUM CLEARANCES TO COMBUSTIBLES
The clearances listed below are Minimum distances unless otherwise stated:
A major cause of fi res is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this
decorative gas appliance be installed only in accordance with these instructions.
PTO28 Clearance Requirements
Clearance:
Dimension
Measured From:
A: Back wall
12" (305mm)
Table Top to back wall
B: Sidewall
12" (305mm)
Table Top to sidewall
C: Ceiling
45" (1143mm)
Table Top to Ceiling
D
1
: Floor
D
2
: Floor
0"
When using supplied leveling legs.
1"(25mm)
Unit Base to Floor
E: Alcove Width
84"(2134mm)
Wall to Wall (Minimum)
F: Alcove Depth
72" (1829mm)
Front to Back Wall (Maximum)
Notes:
0"
No Hearth Required
E
F
Alcove
C
A
B
D