Regency PTO28 City Table Outdoor Gas Fireplace

INSTALLATION

Never insulate around the body of the unit

Excessive heat retention in the fi rebox will lead to component failure
and fi replace malfunction

Excessive heat retention will also increase the risk of fi re inside the
chase

Heat retention can cause “Oil-canning” and damage the fi replace due
to overheating

Do not build up a wall of any type in front or to the sides of the appli-
ance, higher than the fi rebox opening. This will create a pressure zone
at the fi rebox and will prevent the unit from venting

This is an outdoor appliance with a built-in drain. This drain should be
installed and connected in all applications as per the instructions in
this manual

Inadequate drainage will cause rust and reduce the life of your appli-
ance, this is not protected by warranty

Unit shutting down intermittently

Overheating of components leading to failure

• Lifting

fl

ame

Poor fl ame package (i.e. all to one side, lazy fl ame)

Failure to ignite

• Excess

carbon

Safety issues and concerns created from the byproducts of combus-
tion

Outdoor appliances must be installed in: open-air situations with natu-
ral ventilation and without stagnant areas

Any gas leakage and products of combustion need to be rapidly dis-
persed by wind and natural convection

Typically outdoor spaces are not enclosed, however, failure to adhere
to installation guidelines, may cause the outdoor fi replace to be af-
fected by wind or air pressure inside the enclosure

• ANY enclosure in which the appliance is used shall comply with one of

the diagrams on the previous page.

All walls + overhead cover = 100% total area

One of four walls or full overhead area must be totally open, plus—one
of remaining walls must have a fi xed opening

All outdoor fi replaces/fi re tables require total natural ventilation of 50%
open space

Correct Working Gas pressure is critical

Wherever possible avoid locating on a fl at wall in a tight corner

Floor space doesn’t count as “open area”

Install to the manual specs for framing and do not insulate unit or
enclosure

Framing enclosure must at least meet minimum dimensional specs as
per the installation manual

Only Regency approved media should be used in the fi rebox (i.e.
stones/glass)

Be aware of pressure zones due to location (i.e. facing the ocean)

Open walls and doorways to outside air are benefi cial to the perfor-
mance of an outdoor appliance

Fixed roof/ceiling open areas count towards the total open area overall
requirement

Screens create 40% or more air restriction

Screened areas are restrictions and reduce open air space, calculate
area based on a closed screen

The biggest problems are created by lack of airfl ow for the appliance

Outdoor fi replaces are often built-in systems and incorrect installation
can result in high repair costs

Units must not be modifi ed or altered in any way

There is a common misconception that being outdoors, an Outdoor
Fireplace will function, regardless of circumstances,

Outdoor fi replaces require the same amount of ventilation as indoor
units, often more

Outdoor units require adequate ventilation to the atmosphere, which in
turn provides ongoing circulatory combustion air

This type of Appliance Vents.

All Outdoor Fireplace Products have the same need for Air/Oxygen,
and an ability to Vent

Even though the appliance is outdoors, this doesn’t mean it is getting
adequate air

Requirements are not specifi c to Regency units

Read and follow critical location guidelines in this manual

Don’t overlook the obvious

Widen your margin for error

Combustion always requires the same three elements

Only the quantities and volumes change

IMPORTANT INFORMATION FOR OUTDOOR FIREPLACE INSTALLATIONS

IMPORTANT THINGS TO REMEMBER

ANTICIPATED ISSUES CAUSED BY

INCORRECT LOCATION OR INSTALLATION

OUTDOOR APPLIANCES REQUIRE VENTING

COMMON MISCONCEPTIONS REGARDING

OUTDOOR FIREPLACES

UNDERSTANDING OUTDOOR APPLIANCE

REQUIREMENTS

OUTDOOR APPLIANCE INSTALLATION SUMMARY