INSTALLATION

LP HARD LINE CONVERSION

(FOR USE IN PLACE OF LP TANK)

Each Kit contains one LP Hard Line Conversion Kit
Conversion Kit # 286-972 Contains:
Qty. Part

#

Description

1 909-265 Max 0.5 psi label
1 286-035 Regulator mounting base
1 286-036 Regulator mounting top
1 910-054 Regulator LP
1 904-978 3/8” fl ex pipe 18” length
4 904-553 #8 Philips
1

919-229 Instruction sheet

2. Remove LP tank and LP hose from valve.

4. Secure regulator in position with top bracket - secure with 2 screws.
NOTE: Top bracket to sit over top of lower bracket.
Attach supplied "MAX. 0.5 PSI" sticker to top bracket.

1. Remove panel (90º to the right of the ON/OFF switch). Lift panel up slightly

by handle and pull outwards. Place panel on a soft, clean surface.

Remove this

panel

LP hose

Switch

Handle

Regulator

Regulator

Bracket

Top

Bracket

3. Install regulator bracket onto unit base with 2 screws. Connect fl ex line to

regulator—position regulator onto bracket.

Diagram 1

Diagram 2

Location to install

regulator

Access for

Hard line

Diagram 3

Diagram 4

Diagram 5

Turn off unit and allow to cool to room temperature.

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER

IF IN DOUBT DO NOT DO THIS CONVERSION !!