beautypg.com

Maintenance, Installing valve, Removing valve – Regency Panorama P36D Medium Gas Fireplace User Manual

Page 52

background image

52

Regency

®

P36D-1 Zero Clearance Direct Vent Gas Fireplace

MAINTENANCE

11) Undo the pilot tube from the valve with a
7/16"

wrench.

12) Undo the quick drop out thermocouple nut

on the valve with a 9mm (metric) wrench.

13) Remove the Piezo igniter wire and push

button assembly.

14) Undo the "gas out" fl are nut with a 13/16"

wrench.

15) Undo the "gas out" fl are fi tting with an 11/16"

wrench.

16) Remove the 4 Phillips head screws from

the sides of the valve bracket and remove
valve.

Hint:

If you are using black pipe, ensure
that there is a union by the valve,
otherwise removal will be almost
impossible.

INSTALLING VALVE

1) Attach the valve to the valve bracket with

the 4 (m5x8 metric) screws provided.

2) Reconnect the "gas out" fl are fi tting with an

11/16" wrench.

3) Reconnect the "gas out" fl are nut with a
13/16"

wrench.

4) Install piezo ignitor push button assembly

and reconnect wire.

5) Reconnect the quick drop out thermocouple

nut with a 9mm wrench.

6) Reconnect the pilot tube nut with a 7/16"

wrench.

7) Scrape off the old gasket from the fl oor of the

fi rebox and from the valve tray assembly.

8) Install a new gasket and reinstall the valve

tray assembly.

Note:

Failure to install a new gasket
may severely affect the appliance
performance.

9) Reinstall the 10 hold down screws.

10) Hook up the 2 TP and 2 TH wires to the

appropriate connections on the valve.

11) Reinstall the bottom brick panel and the

front log stand.

12) Install Burner/grate assembly

13) Hook up the gas line and check for gas

leaks with a soap and water solution or a
gas leak detector. (Do not use open fl ame
for leak testing.)

14) Fire up the unit temporarily

15) Check the manifold pressure.

16) Reinstall the logs and brick panels as

needed.

17) Close the door and replace the louvers.

18) Fire up the unit again and check for proper

fl ame appearance and glow on logs.

REMOVING VALVE

1) Shut off the gas supply.

2) Remove the louvers (and bay door if it is

on).

3) Open

the

fl ush door and remove the door.

4) Remove the logs.

5) Remove the burner/grate assembly by

removing the two Phillips head screws and
then lift the burner assembly out.

Diagram 1: Remove the left and right screws

and then lift out the

burner/grate assembly.

6) Remove the rear log stand by removing the

2 screws.

Rear Log Stand

screws

8) Disconnect the inlet gas line. See diagram

2.

9) Disconnect the 2 TP wires and the 2 TH

wires from the valve.

10) Remove the 10 Phillips head screws securing

the valve tray assembly in place and then
lift the entire assembly out.

7) Lift out the bottom brick panel.

screws

Valve Tray Assembly