beautypg.com

Installation – Regency Panorama P36D Medium Gas Fireplace User Manual

Page 23

background image

Regency

®

P36D-1 Zero Clearance Direct Vent Gas Fireplace

23

INSTALLATION

Description

Simpson

Direct Vent Pro

®

Selkirk

Direct Temp™

American Metal

Products®

Amerivent Direct

Metal-Fab™

Sure Seal

Security

Secure- Vent®

ICC Excel

Direct

Attic Insulation Shield 12”

46DVA-IS

N/A@ FPI

N/A

4DAIS12

N/A

SV4RSA

N/A

Attic Insulation Shield -

Cold Climates

36”

N/A

N/A

4DAIS12

N/A

N/A

TM-4AS

High Wind Vertical Cap

46DVA-VCH

N/A

N/A

N/A

N/A

TM-4VT

High Wind Horizontal Cap

46DVA-HC

N/A

N/A

N/A

N/A

TM-4DHT

Horizontal Square Termination Cap

See

46DVA-HC

4DT-HHC

4DHC

4DHT

SV4CHC-1

TM-4HT

Vertical Termination Cap

46DVA-VC

4DT-HVC

4DVC

4DVT

SV4CGV-1

TM-4VT

Storm Collar

46DVA-08A

4DT-SC

4DSC

4DSC

SV4FC

TM-SC

Restrictor Disk

N/A

N/A

N/A

N/A

N/A

TM-4DS

Extended Vertical Termination Cap

N/A

N/A

N/A

N/A

N/A

N/A

Chimney Conversion Kit A (USA only)

46DVA-KCA

N/A

N/A

N/A

N/A

TM-4CA6

Chimney Conversion Kit B (USA only)

46DVA-KCB

N/A

N/A

N/A

N/A

TM-4CA7

Chimney Conversion Kit C (USA only)

46DVA-KCC

N/A

N/A

N/A

N/A

TM-4CA8

Chimney Conversion Kit Masonry
(USA only)

46DVA-KMC

N/A

N/A

N/A

N/A

N/A

Wall Firestop

46DVA-WFS

N/A

N/A

N/A

N/A

TM-4TR

Colinear Flex Connectors

46DVA-ADF

N/A

N/A

N/A

N/A

N/A

Adjustable Flashing 0/12-6/12

46DVA-F6

4DT-ST14

4D12S

4DST14

SV4STC14

TF-4FA

Adjustable Flashing 6/12-12/12

46DVA-FLA

4DT-ST36

4D36S

4DST36

SV4STC36

TF-4FB

Vinyl Siding Standoff

46DVA-VSS

4DT-VS

N/A

4DVS

SV4VS

TM-VSS

Vinyl Siding Shield Plate

N/A

4DT-VSP

N/A

N/A

SV4VS

N/A

Snorkel Termination 14”

46DVA-SNKL

N/A

N/A

N/A

N/A

TM-4ST14

Snorkel Termination 36”

N/A

N/A

N/A

N/A

N/A

TM-4ST36

Basic Horizontal Termination Kit (A)

Disc.

4DT-HKA

4DHTK2

4DHTKA

SV-SHK

N/A

Horizontal Termination Kit (B)

46DVA-KHA

(Changed Components)

4DT-HKB

4DHTK1

4DHTKB

SV-HK

N/A

Vertical Termination Kit

Disc.

4DT-VKC

4DHTK

4DHTK

SV-FK

N/A

FPI

946-506/P

Vent Guard (Optional) for AstroCap

946-205

Vinyl Siding Shield for Riser Vent Terminal

510-994

Rigid Pipe Adaptor (Must use with all rigid piping)

946-208/P

Vent Guard (Optional) for Riser Vent Terminal

640-530/P

Riser Vent Terminal

946-523/P

AstroCap Horizontal Cap

946-605

Starter Collar Increaser 4” x 6-5/8” to 5” x 8”

946-206

Vinyl Siding Standoff for AstroCap

Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).

Note: Horizontal runs of vent must be level, or have a 1/4” rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high temperatures and may present a possible fi re hazard.

Offset Pipe Selection: Use this table to determine offset pipe lengths.

Pipe Length

(L)

4” x 6-5/8” Venting

For specifi c instructions on venting components - visit the
manufacturers website listed below.

Run (X)

Rise (Y)

0” (0mm)

4-7/8” (124mm)

13-7/8” (340mm)

Simpson Direct Vent Pro: www.duravent.com

6” (152mm)

8” (203mm)

16-1/2” (419mm)

Selkirk Direct-Temp: www.selkirkcorp.com

9” (229mm)

10-1/8” (257mm)

18-5/8” (473mm)

American Metal Products: www.americanmetalproducts.com

12” (305mm)

12-1/4” (311mm)

20-3/4” (527mm)

Metal-Fab Sure Seal: www.mtlfab.com

24” (610mm)

20-5/8” (524mm)

29-1/8” (740mm)

Security Secure Vent: www.securitychimneys.com

36” (914mm)

29” (737mm)

37-1/2” (953mm)

Industrial Chimney Company: www.icc-rsf.com

48” (1219mm)

37-7/16” (951mm)

45-15/16” (1167mm)

Regency Fireplace Products . 6988 Venture St. . Delta, BC . Canada . V4G 1H4 . 604-946-5155 . www.regency-fi re.com