beautypg.com

Installation, Important message save these instructions, General safety information – Regency Panorama P36D Medium Gas Fireplace User Manual

Page 10: Installation checklist

background image

10

Regency

®

P36D-1 Zero Clearance Direct Vent Gas Fireplace

INSTALLATION

IMPORTANT MESSAGE

SAVE THESE

INSTRUCTIONS

The P36D-NG1 or P36D-LP1 Direct Vent Fireplace
must be installed in accordance with these
instructions. Carefully read all the instructions in
this manual fi rst. Consult the "authority having
jurisdiction" to determine the need for a permit prior
to starting the installation. It is the responsibility of
the installer to ensure this fi replace is installed in
compliance with manufacturer's instructions and
all applicable codes.

GENERAL SAFETY

INFORMATION

1) The appliance installation must conform with

local codes or, in the absence of local codes, with
the current Canadian or National Gas Codes,
CAN1-B149 or ANSI Z223.1 Installation Codes.

2) The appliance when installed, must be

electrically grounded in accordance with local
codes, or in the absence of local codes with the
current National Electrical Code, ANSI/NFPA 70
or CSA C22.1 Canadian Electrical Code.

3) See general construction and assembly

instructions. The appliance and vent should be
enclosed.

4) This appliance must be connected to the

specifi ed vent and termination cap to the outside
of the building envelope. Never vent to another
room or inside a building. Make sure that the
vent is fi tted as per Venting instructions.

5) Inspect the venting system annually for blockage

and any signs of deterioration.

6) Venting terminals shall not be recessed into a

wall or siding.

7) Any safety glass removed for servicing must be

replaced prior to operating the appliance.

8) To prevent injury, do not allow anyone who is

unfamiliar with the operation to use the fi replace.

9) Wear gloves and safety glasses for protection

while doing required maintenance.

10) Be aware of electrical wiring locations in walls

and ceilings when cutting holes for termination.

11) Under no circumstances should this appliance

be modifi ed. Parts that have to be removed for
servicing should be replaced prior to operating
this appliance.

12) Installation and any repairs to this appliance

should be done by a qualifi ed service person.
A professional service person should be called

Emissions from burning wood or gas could
contain chemicals known to the State of
California to cause cancer, birth defects or
other reproductive harm.

INSTALLATION

CHECKLIST

1) Locate appliance

a) Room location (Refer to "Locating Your Gas

fi replace" section)

b) Clearances to Combustibles (Refer to

"Clearances" section)

c) Mantle Clearances (Refer to "Combustible

Mantel Clearances" section)

d) Framing & Finishing Requirements (Refer

to "Framing & Finishing" section)

e) Venting Requirements (Refer to "Venting"

section)

2) Assemble Top Standoffs and Top Facing

Support and Side Nailing Strips (Refer to "Unit
Assembly Prior to Installation" Section). NOTE:
Must be done before installing unit into place.

3) Install vent (Refer to "Venting" sections).

4) Make gas and electrical connections. Test the

pilot. Must be as per diagram (Refer to "Pilot
Adjustment " section).

Convert to propane if desired (Refer to "Gas
Line Installation" and "Conversion Kit from NG
to LPG" sections).

5) Install standard and optional features. Refer

to the following sections:


a. Optional Brick Panels

b. Log Set Installation

c. Standard Flush Door

d.

Regency

®

Flush

e. Remote Control (Optional)

f. Wall Switch (Optional)

g. Wall Thermostat (Optional)

h. Optional Fan Installation

6) Final

check.

to inspect this appliance annually. Make it a practice

to have all of your gas appliances checked
annually.

13) Do not slam shut or strike the glass door.
14) Under no circumstances should any solid fuels

(wood, paper, cardboard, coal, etc.) be used in
this appliance.

15) The appliance area must be kept clear and

free of combustible materials, (gases and other
fl ammable vapours and liquids).