P36D-1 Zero Clearance Direct Vent Gas Fireplace

INSTALLATION

Rigid Pipe Adaptor

Pipe Length

Vertical

Termination

Cap

Storm Collar

Flashing

Ceiling Firestop

24" Pipe

Length

Adj.Pipe Length

11" - 14-5/8"

90 Elbow

o

Horizontal

Termination

Cap

Wall Thimble

Vinyl Siding

Standoff (Optional)

RIGID PIPE VENTING SYSTEMS

Horizontal or Vertical Terminations

The minimum components required for a basic
horizontal termination are:

1 Horizontal

Termination

Cap

1 90

o

Elbow

1 Rigid

Pipe

Adaptor

1 Wall

Thimble

1 Length of pipe to suit wall thickness
(see

chart)

Wall thickness is measured from the back standoffs
to the inside mounting surface of termination cap.
For siding other than vinyl furring strips may be used,
instead of the vinyl siding standoff, to create a level
surface to mount the vent terminal. The Terminal
must not be recessed into siding. Measure the wall
thickness including furring strips.

If a Vinyl Siding Standoff is required (it must be used
with vinyl siding), measure to outside surface of wall
without siding and add 2 inches.

The FPI AstroCap

TM

and FPI Riser Vent terminal are certifi ed for installations using FPI venting systems as well as Simpson Dura-Vent

®

Direct Vent ,

American Metal Products, Security Secure Vent

®

, AmeriVent Direct Vent. AstroCap

TM

is the proprietary trademark of FPI Fireplace Products International

Ltd. Dura-Vent® and Direct Vent are registered and/or proprietary trademarks of Simpson Dura-Vent Co. Inc.

This product has been evaluated by Intertek for
using a Rigid Pipe Adaptor in conjunction with
DuraVent Direct Vent, Selkirk Direct-Temp, Ameri
Vent Direct venting and Security Secure Vent
systems. Use of these systems with the Rigid
Pipe Adaptor is deemed acceptable and does not
affect the Intertek WHI listing of components.

WARNING:

Do not combine venting components from
different venting systems.

However use of the AstroCap

TM

and FPI Riser

is acceptable with all systems.

Flat Wall Installation

Wall Thickness (inches)

Vent Length Required (inches)

4" - 5-1/2"

6"

7" - 8-1/2"

9"

10" - 11-1/2"

12"

9" - 14-1/2"

11" - 14-5/8" Adj. Pipe

15" - 23-1/2"

17" - 24" Adj. Pipe

Corner Installation

Wall Thickness (inches)

Vent Length Required (inches)

3-1/4" - 6-3/4"

11" - 14-5/8" Adj. Pipe

7-3/4" - 16-1/4"

17" - 24" Adj. Pipe

7-1/4" - 8-3/4"

6" + 12"

9" + 9"

4-1/4" - 5-3/4"

6" + 9"

Alternate

Horizontal

Termination