Installation

c

learanceS

to

c

ombuStibleS

:

(229mm)

9"

(76mm)

3"

(76mm)

3"

Side Wall

Back Wall

Adjacent Wall

These dimensions are minimum clearances but it

is recommended that you ensure sufficient room

for servicing, routine cleaning and maintenance.

Side wall to unit 9 inches

(22.9 cm)

Back wall to unit 3 inches

(76 cm)

Corner to unit

3 inches

(76 cm)

Ceiling height

60 inches (152 cm)

Alcove Maximum Depth 36 inches (91 cm)

Alcove Minimum Width 48 inches (122 cm)

Alcove Minimum Height 60 inches (152 cm)

In the USA, the unit must be installed with a

minimum of 6” (152 mm) of floor protection in

front of and to the sides of the door opening.

In Canada, the unit must be installed with a

minimum of 8” (203 mm) of floor protection in

front of and to the sides of the door opening.

figure 4: GC60 Clearance to Combustibles.

t

hermoStat

i

nStallation

:

1. Install the wall thermostat (millivolt rated thermostat

recommended, or a 12/24 Volt rated thermostat set to

millivolts) in a location that is not to close too the unit

but will effectively heat the desired area.

2. Connect the Thermostat using a 2 x 18 gauge wire

from the unit to the thermostat.

If the heat in the room becomes to great, the high limit

switch may turn the stove off and the switch will have to

be manually reset. The switch is found below the firebox

top on the hopper’s right surface.

figure 5: thermostat wire placement.

l

eveling

l

eg

a

djuStment

:

The leveling legs should be adjusted for the unit to to sit level and not rock if installed on uneven

flooring.
1. Turn levelling legs until they are at the required hieghts.
2. Tighten the nut to hold the leveling leg in position.