beautypg.com

Installation – Regency Hampton GC60 Large Pellet Stove TECHNICAL MANUAL User Manual

Page 18

background image

Existing Fireplace

Clean Out Tee

Fireplace Damper

Location

Rain Cap

Seal Plate

Vent Pipe (single wall

stainless flex pipe or

PL vent)

Existing Masonary

Flue

Flexible Vent Connector

(Use this 5 ft section of

pipe to vent past fireplace

damper or smoke shelf)

Floor

Protection

Combustible Floor

Masonry Fireplace

Min (6")

150mm

Mantel

Minimum (8") 200mm

from top of stove

Damper Removed

or Fastened Open

Clean-out tee

Fresh-air intake should com

from chimney. If holes

already exist fresh-air intake

can be taken through back

of the fireplace or through

the ash dump.

Installation

h

earth

m

ount

i

nStallation

:

figure 17: Hearth Mount - side View.

figure 18: Hearth Mount - over View.

1. Lock fireplace damper in the open

position.

2. Install flexible stainless steel liner or listed

pellet vent to the top of the chimney.

All joints in the exhaust venting system

must be fastened with at least three (3)

screws.

3. Install a sealing plate at the top of the

chimney.

4. Connect a rain cap and flex adapter to the

chimney liner/pipe.

5. Connect a clean-out tee or a 90° elbow to

the liner/pipe.

6. Install tee onto stove.

Hampton GC60 Cast Pellet Stove Technical Manual

18