Remote system, Installation – Sportsliter Solutions Remote System User Manual
Page 7

REMOTE SYSTEM
INSTALLATION
6
TWO ROW CROSSARM ASSY.
(Fig. 8)
(QUANTITY OF FIXTURES SHOWN
IS FOR EXAMPLE ONLY)
T
B
BOTTOM ROW
TOP ROW
ONE ROW CROSSARM ASSY. (Fig. 8)
(QUANTITY OF FIXTURES SHOWN
IS FOR EXAMPLE ONLY)
6 4 2 1 3 5
FIXTURE POSITION NUMBERS
ROW IDENTIFICAITON
T = TOP ROW
M = MIDDLE ROW
B = BOTTOM ROW
T
THREE ROW CROSSARM ASSY (Fig. 8)
REFER TO FIGURE 9 FOR DUAL CIRCUIT LAYOUTS
PLUG WIRING ASSIGNMENTS
ELECTRICAL
PLUG
C = LAMP SOCKET
CENTER CONTACT
S = LAMP SOCKET SHELL
5 = FIXTURE POSITION #
Notes:
• FRONT VIEW OF MALE PLUG SHOWN
• FIXTURE POSITIONS ARE MIRRORED
FOR FEMALE PLUG
NOTE THE “D” SHAPE FOR
PROPER PLUG ORIENTAITON
PLUG WIRING ASSIGNMENTS (Fig. 8)
(QUANTITY OF FIXTURES SHOWN
IS FOR EXAMPLE ONLY)
T
M
B
TOP ROW
BOTTOM ROW
MIDDLE ROW
REMOTE BALLAST BOX
FIXTURE POSITION #’s
3
4
5
6
1
2
BALLAST
REMOTE
BALLAST BOX
Standard Remote Layouts
Front View
DUAL CIRCUIT REMOTE LAYOUTS (FIG. 9)
DUAL CIRCUIT REMOTE
BALLAST BOX
CAT. # REMD-1X00H-X-XX-SH
T
M
B
TOP ROW
BOTTOM ROW
MIDDLE ROW
STANDARD REMOTE LAYOUT FOR 19-30 FIXTURE
(FRONT VIEW)
.
6
4
2
1
3
5
T
M
B
T1
B1
ROW ID
FIXTURE POSITION NO.S
2
ND
TIER
1
ST
TIER