Remote system – Sportsliter Solutions Remote System User Manual
Page 6
REMOTE SYSTEM
INSTALLATION
JUNCTION BOX
(CONCRETE POLE OR WOOD
POLE ADAPTION ONLY)
REFLECTORS
MATCH CAT. NO. OF EACH
REFLECTOR WITH LABEL AFFIXED
ON CROSSARM ASSEMBLY AT
EACH POSITION
CROSSARM ASSEMBLY
WIRING HARNESS
ONE PER ARM
(INSIDE POLE,
EXCEPT WOOD POLES,
CONSULT FACTORY)
POLE
BALLAST QTY.
CAT. # REM-1X00H-X- X -SH
2
3
4
5
or
6
REMOTE BALLAST BOX
SUPPLY WIRING TO REMOTE
BALLAST BOX TO BE FURNISHED
BY INSTALLER
POLE LOCATION A1
EACH COMPONENT (EXCEPT REFLECTORS)
IS LABELED WITH POLE ID LABEL (SEE
APPLICATION ENGINEERING DOCUMENTATION
PACKAGE FOR POLE LOCATION)
MATCH BALLAST QUANTITY IN EACH
REMOTE BALLAST BOX WITH QUANTITY
OF FIXTURES ON A CROSSARM ROW
THAT IT WILL SERVICE
INSTALLER SHOULD MARK ON INSIDE OF
EACH REMOTE BALLAST BOX THE CROSSARM
ROW WITH WHICH IT IS CONNECTED
(TOP, MIDDLE OR BOTTOM CROSSARM ROW)
HARNESS INFORMATION
PLUG FROM EACH
CROSSARM ROW
CROSSARM ASSEMBLY ROW ID
T = TOP ROW
M = MIDDLE ROW
B = BOTTOM ROW
REFER TO FIGURE 9 FOR DUAL CIRCUIT LAYOUTS
DUAL LAYOUTS ARE USED FOR BACK TO BACK CROSSARM SYSTEMS
OR FOR SWITCHING FIELD LEVELS. THE REMOTE BOX CATALOG NUMBER
WILL BEGIN WITH ‘REMD’
BALLASTS
Component Matching (Fig. 7)
(Layout shown is for example only)
JUNCTION BOX
(CONCRETE POLE OR WOOD
POLE ADAPTION ONLY)
REFLECTORS
MATCH CAT. NO. OF EACH
REFLECTOR WITH LABEL AFFIXED
ON CROSSARM ASSEMBLY AT
EACH POSITION
CROSSARM ASSEMBLY
WIRING HARNESS
ONE PER ARM
(INSIDE POLE,
EXCEPT WOOD POLES,
CONSULT FACTORY)
POLE
BALLAST QTY.
CAT. # REM-1X00H-X- X -SH
2
3
4
5
or
6
REMOTE BALLAST BOX
SUPPLY WIRING TO REMOTE
BALLAST BOX TO BE FURNISHED
BY INSTALLER
POLE LOCATION A1
EACH COMPONENT (EXCEPT REFLECTORS)
IS LABELED WITH POLE ID LABEL (SEE
APPLICATION ENGINEERING DOCUMENTATION
PACKAGE FOR POLE LOCATION)
MATCH BALLAST QUANTITY IN EACH
REMOTE BALLAST BOX WITH QUANTITY
OF FIXTURES ON A CROSSARM ROW
THAT IT WILL SERVICE
INSTALLER SHOULD MARK ON INSIDE OF
EACH REMOTE BALLAST BOX THE CROSSARM
ROW WITH WHICH IT IS CONNECTED
(TOP, MIDDLE OR BOTTOM CROSSARM ROW)
HARNESS INFORMATION
PLUG FROM EACH
CROSSARM ROW
CROSSARM ASSEMBLY ROW ID
T = TOP ROW
M = MIDDLE ROW
B = BOTTOM ROW
REFER TO FIGURE 9 FOR DUAL CIRCUIT LAYOUTS
DUAL LAYOUTS ARE USED FOR BACK TO BACK CROSSARM SYSTEMS
OR FOR SWITCHING FIELD LEVELS. THE REMOTE BOX CATALOG NUMBER
WILL BEGIN WITH ‘REMD’
BALLASTS
Component Matching (Fig. 7)
(Layout shown is for example only)
5