3 safety, 1 storage, 2 preventative care and maintenance – Schwank 4N/L62-J Pole Mounted User Manual
Page 18

GP-M45J-CX-03D
4N/L51-J,4N/L62-J Manual
RD: Aug 2006
RL: 3D
KH
9.3 SAFETY
• Check periodically for leaks in the system, or immediately when you smell gas.
• In case a leak is detected, extinguish all open flames in the area.
• Never leak test while smoking.
• If you cannot repair a leak, turn off gas supply at the supply valve and contact your gas supplier
or a qualified, licensed gas technician.
• Do not alter or modify this heater in any way
9.1 STORAGE
When heater is not in use for a prolonged period
of time verify that the gas valve is fully and tightly
closed. To avoid damage, the reflector may be
removed.
9.2 PREVENTATIVE CARE AND MAINTENANCE
The burner area is likely to attract spiders, especially inside orifices. Once a year, the heater should be
inspected for spider webs, insects, and debris around burners and orifices. Plugged injectors or orifices
will obstruct the gas flow to the burner. This will result in burner malfunction or possible damage.
Have heater inspected if.…..
• you smell gas combined with yellow tipped flames on burner.
• heater does not provide expected heat capacity
• burner makes little popping sounds while operating, other than when shutting down after
being turned off. When heater is warming up or cooling down a pinging metallic noise is normal.
Page 12