beautypg.com

4 dimensions, 5 selection and ordering data, Dimensions – Robustel M1000 MP User Guide User Manual

Page 11: Selection and ordering data

background image

Robustel GoRugged M1000 MP User Guide


RT_UG_M1000 MP_v.1.0.0

20.12.2013

10 / 41

ESD Protection: 15KV


System

LED Indicators: RUN


Power Supply and Consumption

Power Supply Interface: 2-pin 3.5mm pluggable terminal block

Input Voltage: 6 to 18 VDC (2G model)
6 to 26 VDC (3G model)

Power Consumption: Idle: 50-60 mA@12 V

Data Link: 100 to 200 mA (peak)@12 V


Physical Characteristics

Housing & Weight: Plastic, 105g

Dimension(L x W x H): 75 x 85 x 28 mm

Installation: 35mm Din-Rail or wall mounting or desktop

1.4 Dimensions

1.5 Selection and Ordering Data

Model No.

Description

Operating Environment

Input Voltage

M1000-MP2GA

1 port RS232, GSM/GPRS 850/900/1800/1900 MHz

-40 to 85°C/5 to 95% RH

6 to 18 VDC

M1000-MP2GB

1 port RS485, GSM/GPRS 850/900/1800/1900 MHz

-40 to 85°C/5 to 95% RH

6 to 18 VDC

M1000-MP3HA

1 port RS232, 1 mini USB port, UMTS/HSDPA 900/2100 MHZ, Quad

band GSM/GPRS/EDGE

-40 to 85°C/5 to 95% RH

6 to 26 VDC

M1000-MP3PA

1 port RS232, 1 mini USB port, UMTS/HSPA+ 850/900/1900/2100

MHz, Quad band GSM/GPRS/EDGE

-40 to 85°C/5 to 95% RH