14 • Operation
Diffusion Eagle Instruction Manual
2. Press and briefly hold down the POWER/ENTER button. If the Lunch
Break feature is on (see page 38), the Resume Datalog screen displays.
(If the Lunch Break feature is off, the Battery Voltage screen displays.)
•
Press the AIR/
▲
button to continue accumulating time-weighted
average (TWA) and PEAK readings from the last time the Eagle was
used. (The short-term exposure limit [STEL] reading is reset each
time the Eagle is turned on.) The Battery Voltage screen displays.
•
Press the DISP/ADJ button to restart these measurements. The
Battery Voltage screen displays.
If you do not press the
AIR/
▲
or DISP/ADJ button within 5 seconds, the
Eagle automatically resumes datalog readings and displays the Battery
Voltage screen.
The Battery Voltage screen displays the minimum usable and actual
battery voltage (for example, 6.0V). If the battery voltage is too low, the
Eagle will not continue.