beautypg.com

Figure 7 – Purenex FLECK 5600SXT METER WATER SOFTENER SYSTEMS User Manual

Page 4

background image

- 4 -

Installing the Fleck 5600SXT Meter Control Valve:

Using the included silicone lubricant packet, lubricate the inner and outer o-

rings on the bottom of the Fleck 5600SXT Meter Valve as shown in Figures 5

& 6 below.

FIGURE 5

FIGURE 6

Next, place the Fleck 5600SXT Meter Valve onto the top of the tank, being

sure that the riser tube fits into the central o-ring on the valve, as shown in

figure 7 below. Hand tighten the valve to the tank snugly by hand only.

NOTE: Do not use Teflon tape or pipe dope on the valve or tank threads.






FIGURE 7

Locate the plumbing adaptor that was shipped with your system. Also,

disassemble the plumbing adaptor clips as shown in Figure 8 on the following

page.

Using the included silicone lubricant packet, lubricate the o-rings on the Fleck

5600SXT Meter valve as shown in figure 9 on the following page.

Finally, assemble the plumbing adaptor to the valve as shown in Figure 10 on

the following page. When assembling the clips back onto the valve, leave the

first clip loose. Tighten the second clip, and complete the assembly by

tightening the first clip.