Purenex FLECK 5600SXT METER WATER SOFTENER SYSTEMS User Manual
Page 12

- 12 -
•
The display should now show “RS / SF” as shown in figure 32 below. (This
indicates Reserve Selection is Safety Factor percentage)
Do not change this
value, and press the “Extra Cycle Button” once to continue
.
•
The display should now show “SF / 20” as shown in figure 33 below. (This
indicates the Safety Factor is 20 percent)
Use the “UP” or “DOWN” button to
change this value to “15”, and press the “Extra Cycle Button” once to
continue when finished.
FIGURE 32
FIGURE 33
•
The display should now show “DO / 14” as shown in figure 34 below. (This
indicates the Day Override is 14 days – the system will regenerate on the 14
th
day
if the meter does not otherwise automatically initiate a regeneration based on
usage.)
Do not change this value, and press the “Extra Cycle Button” once to
continue.
•
The display should now show “RT / 2:00” as shown in figure 35 below. (This
indicates the system will regenerate at 2:00 AM, assuming the system clock is set
accurately)
Although this is the recommended time, you may change this by
using the “UP” or “DOWN” buttons, and then press the “Extra Cycle
Button” once to continue.
FIGURE 34
FIGURE 35
•
The display should now show “BW / 10” as shown in figure 36 on the following
page. (This indicates Backwash Time is 10 minutes in length)
Do not change this
value, and press the “Extra Cycle Button” once to continue
.
•
The display should now show “BD / 60” as shown in figure 37 on the following
page. (This indicates Brine Draw Time is 60 minutes)
Do not change this value,
and press the “Extra Cycle Button” once to continue
.