beautypg.com

Maintenance/service – MacDon 922 User Manual

Page 42

background image

Form # 46620

Issue 01/06

40

MAINTENANCE/SERVICE

GREASING THE HEADER AND CONDITIONER

See "Recommended Lubricants" in this section for

recommended greases.

The following greasing points are marked on the

header by decals showing a grease gun (A), and

grease interval (B) in hours of operation. Use the

hour meter in the windrower cab and the

"Maintenance Checklist" provided to keep a record

of scheduled maintenance.

Procedure:

1. Wipe grease fitting with a clean cloth before

greasing, to avoid injecting dirt and grit.

2. Inject grease through fitting with grease gun

until grease overflows fitting, except where

noted. Inject grease slowly to prevent seal

damage.

3. Leave excess grease on fitting to keep out dirt.

4. Replace any loose or broken fittings

immediately.

5. If fitting will not take grease, remove and clean

thoroughly. Also clean lubricant passageway.

Replace fitting if necessary.

10 Hours or Daily:

1. Cross-Shaft Center Support Bearing (D)

- one fitting on Double Sickle Header

25 Hours

1. Sickle Head (C) - single sickle: one fitting

- double sickle: two fittings

NOTE: If more than 6 to 8 pumps of the grease

gun are required to fill the cavity, replace the seal

in the sickle head. When changing seal, check pin

and needle bearing for wear. Replace if necessary.

See page 45.

SAMPLE GREASE DECAL

CROSS-SHAFT CENTER SUPPORT BEARING

DOUBLE SICKLE HEADER

D

SICKLE HEAD

C