Trouble shooting – MacDon 9352i SP User Manual
Page 119

Form # 147141
Issue 02/06 Web Rev_01
117
TROUBLE SHOOTING
 
SYMPTOM 
PROBLEM
SOLUTION
REF.
Air conditioning not 
producing sufficient 
cooling (continued). 
Clogged expansion 
valve. 
Recover system 
refrigerant and replace 
valve. Then, evacuate 
and charge system. 
*
Clogged receiver-drier.
Recover system 
refrigerant and replace 
receiver-drier. Then 
evacuate and charge 
system. 
*
Excessive moisture in 
system. 
Recover system 
refrigerant and replace 
receiver-drier. Then 
evacuate and charge 
system. 
*
Air in system.
Recover refrigerant, 
evacuate and charge 
system. 
*
Thermostat defective or 
improperly adjusted. 
Replace thermostat.
*
Blower motor sluggish 
in operation. 
Remove motor for 
service/replacement. 
*
Air conditioning system 
too noisy. 
Defective winding or 
improper connection in 
compressor clutch coil 
or relay. 
Repair or replace as 
necessary. 
*
Loose or excessively 
worn drive belt. 
Tighten or replace as 
required. 
66
Noisy clutch.
Remove clutch for serv-
ice or replacement as 
required. 
*
Noisy compressor.
Check mountings and 
repair. Remove 
compressor for service 
or replacement. 
*
Compressor oil level 
low. 
Add SP-16 PAG refrig-
erant oil. 
*
Blower fan noisy due to 
excessive wear. 
Remove blower motor 
for service or replace-
ment as necessary. 
*
Excessive charge in 
system. 
Discharge excess 
refrigerant until pressure 
drops within specs. 
(Always recover 
discharged refrigerant.) 
*
 
 
Low charge in system.
Check system for leaks, 
charge system. 
* See your Windrower dealer.