Paxton OEM PROXIMITY architectural reader EM4100 Wiegand output User Manual
Suitability, Fitting, Reader insert removing the reader
Ins-30082 OEM PROXIMITY architectural reader EM4100 Wiegand output
16/11/2011
Suitability
Security-sensitive doors
Wet environments
Readers mounted together
Accepts customised inserts and bezels
between readers
300 mm
Fitting
The reader insert is held against the backplate by an outer decorative bezel secured with 4 small screws.
Remove these screws to release the bezel and refit after adding the insert.
If you have made an insert of less than 5 mm thick, this can still be fitted by using the 3 nylon screws supplied
in the fitting kit to hold the insert against the bezel. (see diagram)
To remove the reader, insert the
tool provided into the cut out
on the underside of the reader.
Push up the clip and pull the
reader from the backbox.
Reader insert
Removing the reader
Ensure that the backbox is mounted vertically and is square with the wall surface.
Care must be taken when doing this, as no further 'twist' adjustment is possible within the reader mountings.
Line up the two locating pins on the top of the
reader with the top plate inside the backbox.
Once located, the reader can be clipped into the
box at the bottom using the clip feature.
Check that the reader is located against the
surface of the wall. If there is a gap between
the reader and the wall, or if the reader will
not successfully clip into the box, remove the
reader and adjust the mounting plates inside the
backbox using a 3 mm Allen key.
Mounting the reader