Door open time (seconds), Silent operation, Specifications – Paxton PROXIMITY vandal proof compact reader User Manual
Page 4: Yes yes, Beep

Door open time (seconds)
1. Take the silent operation function card from the starter pack.
2. Present the card to the reader. The reader will beep.
3. The reader is now in silent operation mode.
4. Present the card again to disable silent operation mode. The reader will beep twice.
Silent operation
1. Take the 'door open time' card from the starter pack.
2. Present the card to the reader. The reader will start beeping.
3. Wait for the required period you wish the door to remain open.
4. Present the card again at the end of the period to set the open time. The beeping will stop.
1
2
3
4
BEEP!
BEEP!
BEEP!
Paxton A
ccess
FUNCTION CARD
silent o
peration
Present
this c
ard to silenc
e t
he b
eep
ing no
ises
made b
y the r
ea
der
. P
resent
this card a
gain t
o
re-ena
ble t
he b
eep
ing no
ises
Paxton A
ccess
FUNCTION CARD
silent o
peration
Present
this c
ard to sil
enc
e t
he b
eep
ing no
ises
made b
y the r
ea
der
. P
resent
this card a
gain t
o
re-ena
ble t
he b
eep
ing no
ises
FUNCTION CARD
silent operation
Present this card to silence the beeping noises
made by the reader. Present this card again to
re-enable the beeping noises
1
2
3
4
BEEP!
BEEP!
Paxton
Access
FUNCTION CARD
door
open time card
The
period that
the
door
is unlocked for when a
va
lid token is presente
d is set as follows:
1.
Present this
card
2.
Wa
it for the required
period
3.
Present this
card ag
ain, the
beeping
will stop
Paxton
Access
FUNCTION CARD
door open time card
The period that the door
is
unlocked f
or when
a
valid token is
presented is
se
t as
follows:
1.
Present this ca
rd
2.
Wa
it for the r
equired peri
od
3.
Present this
card
again, the beeping will
stop
FUNCTION CARD
door open time card
The period that the door is unlocked for when a
valid token is presented is set as follows:
1. Present this card
2. Wait for the required period
3. Present this card again, the beeping will stop
Voltage
1
10,000
1
100
1 sec
60 secs
1
2
1
3
11V DC
14V DC
160mA
1A
-20 °C
+55 °C
IPX7
20 mm
60 mm
80 mm
40 mm
Specifications
Operating temperature
Electrical
Environment
Dimensions
Min
Max
Diameter
Depth
Current
Outdoor Use
Features
Door open time
Number of Card Packs
Time zones (with additional time clock)
Silent operation
Can be used with fail OPEN locks
Can be used with fail CLOSED locks
Exit button input
Waterproof
Number of Users
Access levels (Colour Zones)
Switchable current
Min
Min
Max
Max
The declaration of conformity is available on request. Contact details are provided at:
http://paxton.info/596
Yes
Yes
Yes
Yes
Cable length
3 metres
Read Range
Token
Keyfob
Hands Free Token
Not Compatible