To delete a card pack

Factory reset

1. Power down the unit.

2. Press and hold down the exit button.

3. Power up the unit and release the exit button. The reader will beep and the red LED will come on.

4. After 3 seconds the unit will beep 3 times again and all the LED's will come on.

User cards are NOT supplied with this unit. Please supply your own user cards.

Compatible with any Track 2 ISO magstripe card

1. Card packs may be deleted from the system if required. Once a card pack has been deleted another one may

be enrolled in its place.

2. To delete a card pack, take the master card and swipe it backwards through the reader. The LEDs should then

start to flash in sequence, one after the other.

3. During this phase, swipe the master card backwards again and the reader will beep once and the LEDs will all

come back on.

4. The card pack will now have been removed from the system

Fail Open release card - (Unit default = Fail Closed)

THIS CARD CAN ONLY BE USED WITH A FAIL OPEN LOCK.

1. Take the fail open release function card from the starter pack.

2. Present/swipe the card through the reader. The reader will beep for about a second.

3. The reader is now set to fail open mode. This allows safe operation of the door in case of fire: The lock will

release when the power is cut.

4. To revert to fail closed mode, swipe the card again and the reader will beep once.

BEEP!

BEEP!

1

2

3

4

This card is used with systems where a fail open

electric release is used for the safe operation in the

event of a fire. Present the card to the reader to

drive a fail open release or a maglock. Present the

card again to revert to the fail closed operation

FUNCTION CARD

fail open release