Status lights specifications, Features, Warnings – Paxton 24V AC/DC power supply with Net2 ACU User Manual
Page 3
Page 3
13.8V DC
24V DC
2 A
0.75 A
24 W
0.5 A
3.5 hours
24V AC or DC
2.3 A
50 Hz
60 Hz
0 °C
+49 °C
0 °C
+40 °C
232mm
320mm
80mm
236mm
320mm
80mm
150mm
100mm
62mm
:
The following warnings and instructions MUST be adhered to. Read the instructions before installing and powering the
equipment. Keep the instructions in a safe place for future reference.
:
RECEIVING INSPECTION- Remove any traces of packing material from the unit as such debris may create a fire or shock hazard.
Unpack the unit with care and inspect for transit damage. If damage is suspected, the unit must not be used or tested, but should be
returned to Paxton for investigation and the damage reported to the carrier.
:
INSTALLATION- Only qualified and trained personnel, familiar with this type of product and who fully understand these instructions
should install, connect or test this equipment. There are no user serviceable parts within the PSU unit.
:
- The equipment is intended for indoor use only in dry locations.
:
- This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required
to take adequate measures.
:
- The installation must meet National Wiring Regulations and IEC60950-1 standards. A readily accessible disconnect device shall be
incorporated in the building wiring to include a 2.5A rated circuit breaker with at least a 3.0 mm contact gap.
Maximum 12V DC load output current
12V Output voltage
24V Output voltage
Maximum 24V DC load output current
Total power out (combined outputs)
Maximum battery charging current
Input supply voltage
Input supply current
Input supply frequency
Maximum battery life at full load (2A)
Registers an alarm if the input power fails when connected to an ACU or I/O board.
Input supply failure (PSU)
Status Lights
Specifications
PSU Electrical
Features
The declaration of conformity is available on request. Contact details are provided at:
http://paxton.info/596
Green
Red
Battery backup
Fast/Trickle charge
Deep discharge protection
Tamper alarm
This LED is on when the input supply has failed - Power is being supplied by the battery.
This LED is on when the input supply is healthy.
The cabinet can accommodate a 12V / 7Ah battery.
The battery is continuously charged to keep it at maximum capacity.
If battery voltage falls below 9.5V, it will automatically disconnect - Red LED goes out.
Registers an alarm if the lid is opened when connected to an ACU or I/O board.
Environment
Metal Cabinet
Plastic Cabinet
Battery Compartment (Plastic Housing)
Dimensions
WARNINGS
Min
Max
Width
Height
Depth
Waterproof
No
ACU Electrical
Min
Max
See accompanying documentation ( ins-30000 - Net2 classic, ins-30075 - Net2 nano, ins-30080 - Net2 plus )
Operating temperature - no battery backup
Operating temperature - with battery