Paxton Access Ltd hereby declares that this product is in conformity with all the essential requirements of Directive

1999/5/EC. This equipment is intended for use in all EU and EFTA countries and all other countries worldwide.

10V DC

14V DC

130 mA

115 kHz

135 kHz

-35 °C

+66 °C

IPX7

45 mm

100 mm

20 mm

85 mm

Voltage

Carrier frequency

Specifications

Operating temperature

Electrical

Environment

Dimensions

Min

Max

Width

Height

Depth

Current

Cable length

Read Range

Token

Hands Free Token

Waterproof

Min

Max

Wiring

Connection to a Net2

ACU reader port

+12V DC
Red LED

Amber LED
Green LED

Clock/data1

Data/data0

Not required
0V

Token type and configuration

The reader will recognise 125 kHz HID

TM

proximity tokens in format to produce a Wiegand output (26 to 50 bit) or

EM4100 tokens to produce a Clock and Data output.

The reader scans the first token presented after power up and will match the reader mode to the format discovered.

If no token is read within 3 minutes of powering up, the reader will default to HID

TM

. If you require EM4100

operation, power cycle the reader and present an EM4100 token within 3 minutes.

Once in HID

TM

or EM4100 mode, the reader will remain in that format.

The declaration of conformity is available on request. Contact details are provided at:

http://paxton.info/596

Not Compatible

If used with Net2, the ACU reader port must be configured to read the correct data format.

Where Wiegand cards are used, you must set the correct data format (e.g. Wiegand 26 bits) in the ACU

reader port configuration or create a custom wiegand filter in the Net2 Server Configuration Utility. For further

information see

: AN1010 - Configuring custom Wiegand formats <

http://paxton.info/990

>

3 metres

Outdoor use