Dca-85ssju — output terminal panel overview – Multiquip DCA85SSJU User Manual
Page 39
DCA-85SSJU — PARTS AND OPERATION MANUAL— REV. #2 (12/21/01) — PAGE 39
Voltage Selector Switch- Single Phase 240/120V
Position
The following are additional voltages available when the
voltage selector switch is in the single phase 240/120V
position. (See Figure 34 below)
Single Phase, 240 Volt
The following connection, with the voltage selector switch
locked into the single phase 240/120V position (See
Figure 34), will offer SINGLE PHASE power at 240V. After
hooking up the hard wires to the lugs as shown in figure 36
below, use the Voltage Regulator Knob to fine tune to
240V. (See Figure 35)
Single Phase: 120 Volt
The following connection, with the voltage selector switch
locked into the single phase 240/120V position (See
Figure 34), will offer SINGLE PHASE power at 120V. After
hooking up the hard wires to the lugs as shown in figure 37
below, use the Voltage Regulator Knob to fine tune to
120V. (See Figure 35).
FIGURE 34. Voltage Selector Switch 240/120V Single Phase
Position
FIGURE 36. Hard Wire Hook-up for Single Phase 240 volt
FIGURE 37. Hard Wire Hook-up for Single Phase, 120 volt
FIGURE 35. Voltage
Regulator Knob located
on the control panel
DCA-85SSJU — OUTPUT TERMINAL PANEL OVERVIEW