beautypg.com

Dca-85ssju — output terminal panel overview – Multiquip DCA85SSJU User Manual

Page 35

background image

DCA-85SSJU — PARTS AND OPERATION MANUAL— REV. #2 (12/21/01) — PAGE 35

How to read the output terminal gauge.
The gauge and knobs on the control panel DO NOT effect
the generator output . They are to help observe how
much power is being supplied produced at the UVWO
legs.

When the Voltage selector switch is in the 240/120V
position (see Figure 15), place the AC Voltmeter Change-
over switch to the W-U position and the AC ammeter
Change -over Switch to the U or W position to read the
output on the selected leg.

A

0

40

60

75

20

FIGURE 15. Voltage Selector Switch 240/120V Single Phase

Position

FIGURE 16. AC Voltmeter

Change-over switch

(Reading the W-U leg on

the outputerminal panel)

FIGURE 19. AC Ammeter

(Amp reading on U lug)

FIGURE 18. AC Ammeter

Change-over Switch

(Reading the U leg on the

output terminal panel)

FIGURE 17. AC Voltmeter

Gauge

(Volt reading on W-U Lug)

When using plural single phase
voltages, make sure to balance
the load on each of the single
phase legs.

NOTE

DCA-85SSJU — OUTPUT TERMINAL PANEL OVERVIEW