Specifications – Multiquip 900HD~2600HD User Manual
Page 10
![background image](/manuals/568922/10/background.png)
page 10 — FLeXSHaFTS/VIBRaTOR HeaDS • OpeRaTIOn anD paRTS manuaL — ReV. #0 (07/16/10)
specificatiOns
Table 4. Drive motors (electric/gasoline)
model#
amps
Voltage/Frequency
Hp (kW)
Rpm
Required
Shaft
Type
CV1
10
120 VAC 50/60 Hz
1 (1.2)
16,000
314V
Electric
CV2
15
120 VAC 50/60 Hz
2 (1.8)
18,000
382V/FS
Electric
CV2E
7.5
240 VAC 50/60 Hz
2 (1.8)
18,000
382V/FS
Electric
CV3
20
120 VAC 50/60 Hz
3 (2.4)
19,250
382V/FS
Electric
CV3E
10
240 VAC 50/60 Hz
3 (2.4)
19,250
382V/FS
Electric
G55H
N/A
N/A
4.8 (3.6)
3,600
382V/FS
Gasoline
BP25H
N/A
N/A
2.1 (1.6)
7,000
382V/FS
Gasoline
NOTICE
Vibration techniques, vibrator head placement and
spacing as referenced in the "General Information" and
"Operation" sections of this manual is only to be
used
as a guidline. Multiquip assumes no responsibility for
vibrator operating techniques referenced in this manual.
The consoldation of concrete has many mitigating
factors that must be considered such as slump, mix,
depth of vibrator, vibrator spacing, vibration time,
vibration frequency, temperature. All of these factors
must be considered when the consildation (vibration)
of concrete is required.