Maintenance – Multiquip LS-300P User Manual
Page 50

PAGE 50 — MAYCO LS300P CONCRETE PUMP • OPERATION MANUAL — REV. #0 (06/09/14)
Wear Plate Installation
1. Install the two cylinder
o-rings.
2. Using silicon sealant, coat the circumference of the
concrete cylinders, the back of the wear plate and
around the five bolt holes. Next, install the wear plate
and the five bolts. The bolts must all be equally snugged
and tightened to 100 foot pounds each.
Wear Ring Installation
1. Install the wear ring into the
nun plate.
2. Install the steel insert ring inside of the rubber energizer
ring.
3. Install the energizer ring assembly into the nun plate.
4. After installing the above mentioned components
the machine can be reassembled by reversing steps
1 through 5 of the Wear Plate and Cutting Ring
Replacement Procedure.
Heat Exchanger Cooling Fan
This section is intended to make sure the cooling fan is
working properly. Under normal conditions the fan should
be running any time the engine is turned on.
Pressure Test
1. To determine the pressure of the hydraulic system,
set the
cylinder stroke control switch (Figure 52) to
the
JOG position.
Figure 52. Cylinder Stroke
Control Switch (JOG)
NOTICE
If the hydraulic oil temperature exceeds 170° F (77° C),
shut down the pump.
DO NOT continue to operate the
pump. Failure to shut down the pump will result in severe
damage to the pump.
AUTOMATIC
JOG
CENTER
OFF
2. Place and hold the
manual cylinder jogging switch
(Figure 53) to either
JOG “A” or JOG “B” position to
test the pressure of that cylinder.
Figure 53. Manual Cylinder Jogging Switch
3. The
pumping pressure gauge (Figure 54) should
read approximately 3100 ~ 3200 PSI.
Figure 54. Pumping Pressure Gauge
JOG
“A”
JOG
“B”
CYLINDER STROKE
0
PUMPING
PRESSURE
1000
2000
3000
5000
4000
MAINTENANCE