Operation – Multiquip C10PH8 User Manual
Page 21

C10SH8-PH8 CONCRETE MIXER • OPERATION AND PARTS MANUAL — REV. #0 (03/06/09) — PAGE 21
OPERATION
OPERATION
To position the tub, make sure the mixer is placed on
1.
fi rm level ground, then pull up on the dump latch
(Figure 13) and turn the hand wheel until the tub is at
the desired position. Once the tub is at the desired
position, pull down on the dump latch to lock the tub
in position.
Mixing Drum Position
Figure 13.
As the drum rotates, use a shovel (Figure 14) to place
2.
the cement mix inside the drum, add water as required.
Be careful to only place the tip of the shovel inside the
drum.
Filling Mixing Drum
Figure 14.
PULL UP TO RELEASE
PULL DOWN TO LOCK
ROTATE TO
POSITION TUB
HAND
WHEEL
Filling Mixing Drum Incorrectly
Figure 15.
STOPPING THE MIXER
Push the main start/stop switch (Figure 16) inward to
1.
stop the engine.
Start/Stop Button (Stop Position)
Figure 16.
Place fuel shut-off lever in the OFF position.
2.
Clean drum of all debris and foreign matter.
3.
CAUTION
Placing the shovel all the way inside the drum will cause
the shovel to strike the blades. This condition will make
the shovel rotate, and cound cause injury to personnel.
NEVER place hands inside the mixing drum while it is
rotating (Figure 15).