Ga6hr/ga6hrs— nameplate and decals assy, Ga6hrs ga6hr, Danger – Multiquip GA-6HRS User Manual
Page 42: Operation switch, Quartz 0n off idle control
pAgE 42 — ga6HR/ga6HRS 60 hz gENERATOR• OpERATiON ANd pARTs mANuAl — REv. #0 (08/12/14)
GA6HR/GA6HRS— NAmEPlATE AND DECAlS ASSy.
S-1123
To avoid injury,
you MUST read
and understand
operator’s manual
before using this
machine.
Ask for training
as needed.
This machine to
be operated by
qualified
personnel only.
WARNING
Only qualified personnel should
install, use or service this
equipment.
DANGEROUS
GAS
S-4984
WARNING
Only operate machine in well ventilated
areas.
DO NOT inhale exhaust gases.
Only qualified personnel should
install, use or service this
equipment.
S-4985
DANGER
Do not touch output terminals or
internal wiring while unit is operating.
Turn off power before servicing.
Only qualified personnel should
install, use or service this
equipment.
ELECTRICAL
SHOCK
HAZARD
CAUTION
OPERATE AT
3600 RPM ONLY
(
FULL THROTTLE
)
DAMAGE MAY RESULT IF
OPERATED AT LOWER SPEEDS
WARNING
B e f o r e c o n n e c t i n g t h i s
g e n e r a t o r t o a n y b u i l d i n g ’ s
e l e c t r i c a l s y s t e m , a l i c e n s e d
e l e c t r i c i a n m u s t i n s t a l l a n
i s o l a t i o n ( t r a n s f e r ) s w i t c h .
S e r i o u s i n j u r y o r d e a t h m a y
r e s u l t w i t h o u t t h i s t r a n s f e r
s w i t c h .
A91110010
DANGER
Using a generator indoors CAN KILL YOU IN MINUTES.
Utilser un générateur à l’ intérieur VOUS TUERA EN QUELQÙES MINUTES.
120
V
OF
F
GAC-2.2H
POWERED by
Honda Engines
11250AV
GR TPERRIS
REE DE
A
CC
IO
N U
C
TE
R
IRR
ACR
NUU
TIT
P
P TB
RER
IU
NER
CA ID
P
KA
E
ELR
NEUTRAL BONDED TO FRAME
LNAE UCTARREC M
AS
ISS A
E LDAU M
MAOSTSEEU A
R
211052
120
V
OF
F
GAC-2.2H
POWERED by
Honda Engines
11250AV
GR TPERRIS
REE DE
A
CC
IO
N U
C
TE
R
IRR
ACR
NUU
TIT
P
P TB
RER
IU
NER
CA ID
P
KA
E
ELR
NEUTRAL BONDED TO FRAME
LNAE UCTARREC M
AS
ISS A
E LDAU M
MAOSTSEEU A
R
211052
120
V
OF
F
GAC-2.2H
POWERED by
Honda Engines
11250AV
GR TPERRIS
REE DE
A
CC
IO
N U
C
TE
R
IRR
ACR
NUU
TIT
P
P TB
RER
IU
NER
CA ID
P
KA
E
ELR
NEUTRAL BONDED TO FRAME
LNAE UCTARREC M
AS
ISS A
E LDAU M
MAOSTSEEU A
R
211052
NEVER use in enclosed or partially
enclosed areas.
Utilisation INTERDITE dans un
espace clos ou partiellement clos.
ONLY use outdoors and away from
open windows, doors, and vents.
Utilisation UNIQUEMENT à l’ extér leur
portes et trous d’ aération
Exhaust contains carbon monoxide, a poison gas you cannot see or smell.
Les gaz d’ échappement contiennent du monoxyde de carbon, un gaz toxique
invisible et inodore.
A90400001
GROUND ROD
FOR EARTH
GROUND
CONNECT TO
BUILDING
GROUND
IF REQUIRED
8 FT. MINIMUM
REFERENCE
NEC 250-52(C)
AC CIRCUIT
BREAKER
120/240V
30A
120V
30A
20A
20A
0N
OFF
IDLE
CONTROL
OPERATION
SWITCH
ON
OFF
FULL POWER
SWITCH
120V
120V/240V
120
V
OFF
21A
GA-6H
6000
GROUND
SCREW
GROUND
CABLE
#8 MINIMUM
DANGER
THE POSSIBILITY EXISTS OF ELECTROCUTION IF
GENERATOR/WELDER IS NOT PROPERLY GROUNDED.
ALWAYS CONNECT EARTH GROUND (GROUND
ROD) TO GENERATOR GROUND POINT.
FOR FURTHER GROUNDING
INSTRUCTIONS, READ MANUAL
D9531100104
WARNING
Operation of this equipment may create
sparks that can start fires around dry
vegetation.
A spark arrestor may be required.
The operator should contact local fire
agencies for laws or regulation relating
to fire prevention requirements.
M90420000
3
5
ON
ON
S-3704
FUEL COCK
1. Before starting check the oil and fuel level.
2. Switch the circuit breaker to the “OFF” position.
3. Open the fuel valve.
4. Pull the choke knob.
5. Turn the operation switch to the “ON” position
and push the start button to start the engine.
6. After the engine starts, gradually push in the choke knob.
7. Run the generator for 3-5 minutes without load.
8. Check for any abnormal noise or smell.
9. Switch the circuit breaker to the “ON” position.
10.When stopping, cut-off the load and allow the unit
to cool for 2-3 minutes before stopping engine.
11.Turn the operation switch to the “OFF” position.
12. After the engine completely stops, close the fuel valve.
OPERATING INSTRUCTIONS
A55100000
1
1. Before starting check the oil and fuel level.
2. Switch the circuit breaker to the “OFF” position.
3. Open the fuel valve.
4. Pull the choke knob.
5. Turn the operation switch to the “ON” position.
6. Pull the recoil starter.
7. After the engine starts, gradually push in the choke knob.
8. Run the generator for 3-5 minutes without load.
9. Check for any abnormal noise or smell.
10.Switch the circuit breaker to the “ON” position.
11.When stopping, cut-off the load and allow the unit
to cool for 2-3 minutes before stopping engine.
12.Turn the operation switch to the “OFF” position.
13. After the engine completely stops, close the fuel valve.
OPERATING INSTRUCTIONS
A92120010
GA6HRS
GA6HR
2
CLEAN ELEMENT EVERY 50 HOURS (EVERY
10 HOURS UNDER DUSTY CONDITIONS.
WASH IN HIGH FLASH-POINT SOLEVENT
SQUEEZE DRY, THE DIP IN CLEAN ENGINE
OIL AND SQUEEZE OUT EXCESS OIL.
AIR CLEANER MAINTENANCE
12
16
S-2090
S-2091
17
14
15
18
BATTERY
CAPACITY 12V 26 Ah
CONNECTION (+) STARTER
(-) EARTH
KEEP COVER ON THE BATTERY
WHEN DURING OPERATION.
S-1237
7
8
MODEL
SERIAL NO.
6
4
0N
OFF
IDLE
CONTROL
OPERATION
SWITCH
ON
OFF
GA-6HR
AC VOLTMETER
120V
30A
120/240V
30A
120V
20A
AC CIRCUIT BREAKER
GFCI PROTECTED
120V
240/120V
FULL POWER
SWITCH
20A
120V
20A
120V
A51120280
0N
OFF
IDLE
CONTROL
GA-6HRS
AC VOLTMETER
120V
30A
120/240V
30A
120V
20A
AC CIRCUIT BREAKER
GFCI PROTECTED
120V
240/120V
FULL POWER
SWITCH
20A
120V
20A
120V
A51120300
OPERATION
SWITCH
START
SWITCH
QUARTZ
0N
OFF
IDLE
CONTROL
GA-6HRS
MANUAL RESET
P
O
W
E
R
F
A
U
L
T
120
V
120
AC VOLTMETER
120V
30A
120/240V
30A
120V
20A
AC CIRCUIT BREAKER
GFCI PROTECTED
120V
240/120V
FULL POWER
SWITCH
20A
120V
20A
120V
START
SWITCH
OPERATION
SWITCH
IDLE
CONTROL
6kW
13
LO
CK
PIN
P/N A351000010
9
10
11