QP-204H CENTRIFUGAL PUMP — OPERATION AND PARTS MANUAL— REV. #3 (06/05/06) — PAGE 9

QP-204H — RULES FOR SAFE OPERATION

Maintenance Safety:
NEVER lubricate components or attempt service on a

running machine.

ALWAYS allow the machine a proper amount of time to

cool before servicing.

■ Keep the machinery in proper running condition.
■ Fix damage to the machine immediately and always replace

broken parts.

■ Dispose of hazardous waste properly. Examples of

potentially hazardous waste are used motor oil, fuel and
fuel filters.

DO NOT use food or plastic containers to dispose of

hazardous waste.

DO NOT pour waste, oil or fuel directly onto the ground,

down a drain or into any water source.

EMERGENCIES
ALWAYS know the location of the

nearest

fire extinguisher

.

ALWAYS know the location of the nearest

first aid kit

.

■ In emergencies always

know the location of the

nearest phone or

keep a phone on the job site

.

Also know the phone numbers of the nearest

ambulance

,

doctor

and

fire department

. This

information will be invaluable in case of an
emergency.

NEVER run engine without air cleaner. Severe engine damage

may occur.

ALWAYS read, understand, and follow procedures in

Operator’s Manual before attempting to operate equipment.

ALWAYS be sure the operator is familiar with proper safety

precautions and operation techniques before using pump.

ALWAYS store equipment properly when it is not being used.

Equipment should be stored in a clean, dry location out of the
reach of children.

NEVER leave the pump unattended, turn off engine when

unattended.

■ Unauthorized equipment modifications will void all

warranties.

NEVER pump volatile, explosive, flammable or low flash

point fluids. These fluids could ignite or explode.

NEVER operate the pump in an

explosive

atmosphere.

■ Before starting the pump, check that the clean-out cover is

securely fasten.

ALWAYS ensure pump is on level ground before use.
■ Become familiar with the components of the pump before

operating.

ALWAYS replace any worn or damaged warning decals.
NEVER pump corrosive chemicals or water containing toxic

substances. These fluids could create serious health and
environmental hazards. Contact local authorities for
assistance.

NEVER open the priming plug when

pump is hot. Hot water inside could be
pressurized much like the radiator of an
automobile. Allow pump to cool to the
touch before loosening plug.

The

possibility exists of scalding, resulting
in severe bodily harm.

NEVER disconnect any "emergency or safety devices".

These devices are intended for operator safety. Disconnection
of these devices can cause severe injury, bodily harm or even
death! Disconnection of any of these devices will void all
warranties.

TRANSPORTING
ALWAYS shutdown engine before transporting.
■ Tighten fuel tank cap securely and close fuel cock to prevent

fuel from spilling.

■ Drain fuel when transporting pump over long distances or

bad roads.

ALWAYS tie down the pump during transportation by securing

the pump's guard frame with rope.

NEVER open the pump housing during operation or start the

pump with the clean-out cover removed. The rotating impeller
inside the pump can cut or sever objects caught in it.

NEVER block or restrict flow from discharge hose. Remove

kinks from discharge line before starting pump. Operation
with a blocked discharge line can cause water inside pump
to overheat.

ALWAYS fill the pump casing with water before starting the

engine. Failure to maintain water inside the pump housing
will cause severe damage to the pump.

■ In winter drain water from pump housing to prevent freezing.