beautypg.com

Pumping application, Total suction head, Total discharge head – Multiquip MP200SDLSM Operation Manual User Manual

Page 22: Total head

background image

PAGE 22 —DRY PRIME PUMP — OPERATION MANUAL — REV. #3 (10/06/08)

PUMPING APPLICATION

Figure 6 shows a typical application using the Dry Prime
diesel-powered prime-assist pump. Please note that this
pump is intended for the removal of clean water and water
containing some debris and solids. Maximum size of solids
should not exceed 3.2 inches (81.2 mm) in diameter. DO
NOT
set strainer on bottom of water bed.

Placing the strainer above the water bed will prevent the
pump from drawing in excessive amounts of sand and foreign
debris.

The following terms are usually used when referring to

lift or

head:

1.

Static Suction Lift – The vertical distance from the
water line to the center of the impeller.

2.

Static Discharge Head – The vertical distance from
the discharge outlet to the point of discharge or liquid
level when discharging into the bottom of a water tank.

Figure 6. Pump Application

3.

Dynamic Suction Head – The static
suction lift plus the friction in the suction
line. Also referred to as

total suction

head

.

4.

Dynamic Discharge Head – The static
discharge head plus the friction in the
discharge line. Also referred to as

total

discharge head

.

5.

Total Dynamic Head – The Dynamic Head
Suction Head plus the Dynamic Discharge
Head. Also referred to as

total head

.

SUCTION HOSE

STRAINER

CHOCKED

BLOCKS

(PREVENT ROLLING)

BOTTOM

SURFACE

DO NOT LAY
STRAINER ON
BOTTOM SURFACE

STATIC

SUCTION

LIFT

JACK

STAND

DISCHARGE HOSE

DISCHARGE HEAD

JACK

STAND

JACK

STAND