beautypg.com

MTS Landmark Site Prep Guide User Manual

Page 21

background image

Hydraulic Power Unit Specifications

Landmark Test System Site Prep Guide

System Component Specifications

21

Model Specific Specifications

Parameter

505.20 Specification

505.30 Specification

Pump/Motor

Maximum continuous
pressure

Maximum flow
capacity

Motor rating

Current draw

Operating voltages

Control voltage

Type NEMA compliant

21 MPa (3000 psi)

75 L/m (20 gpm) at 60 Hz
62 L/m (16.5 gpm) at 50 Hz

30 kW (40 hp) at 50/60 Hz

52 A continuous at 460 V AC 3Ø
66 A continuous at 380 V AC 3Ø

200–575 V AC

24 V DC

Type NEMA compliant

21 MPa (3000 psi)

113 L/m (30 gpm) at 60 Hz
101 L/m (26.6 gpm) at 50 Hz

45 kW (60 hp) at 50/60 Hz

77 A continuous at 460 V AC 3Ø
97 A continuous at 380 V AC 3Ø

200–575 V AC

24 V DC

Water flow rating
(input temperature)

15.5°C (60°F)

21.1°C (70°F)

26.7°C (80°F)

32.2°C (90°F)

Heat load (maximum)

23.4 L/m (6.26 gpm)

30.2 L/m (8.06 gpm)

42.7 L/m (11.3 gpm)

60.4 L/m (16 gpm)

31.65 kW (108,000 Btu/hr)

35.2 L/m (9.3 gpm)

45.4 L/m (12 gpm)

64.7 L/m (17.1 gpm)

91.2 L/m (24 gpm)

49.2 kW (168,000 Btu/hr)

Weight

Empty

With 227 L (60 gal) oil

542 kg (1195 lb)

733 kg (1615 lb)

588 kg (1295 lb)

778 kg (1715 lb)