Routine maintenance overview checklist, Routine maintenance overview checklist 58 – MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-30 User Manual
Page 58

Model 505G2.20 - 505G2.30 SilentFlo™ HPU
58
Routine Maintenance Overview Checklist
Maintenance
Routine Maintenance Overview Checklist
Recommended service to be performed at each running time interval noted
Calendar Time using 8 hour
Running Time rate per day
Daily
Weekly
Monthly
Annually
Running Time-Hours
8
40
160
500
1000 1,500 2,000
5,000 10,000
Check electronic enclosure
ventilation
X
*
Check dirty filter indicators
X
Check for leaks
X
Check oil level
X
Check pressure
X
Check fluid color and odor
X
Check interlock devices
X
Check cables and connectors
X
Check console air filter
MTS
†
Check all accumulators for
proper precharge pressure
and oil
MTS MTS MTS
MTS
Check condition of all
electrical cables and cable
connections
MTS MTS MTS
MTS
Check HPU hydraulic fluid
color and odor
MTS MTS MTS
MTS
Check HPU operating
pressure and temperature
MTS MTS MTS
MTS
Clean control cabinet air filter,
replace if required
MTS MTS MTS
MTS
Inspect heat exchanger for
leaks or “flow (when off)”
MTS MTS MTS
MTS
Inspect pump hoses for leaks
MTS MTS MTS
MTS
Lubricate-grease motor
bearings (non 505)
MTS MTS MTS
MTS
Verify dirty filter indicators
status
MTS MTS MTS
MTS
Verify HPU hydraulic fluid
level
MTS MTS MTS
MTS
Verify warning and interlock
devices
MTS MTS MTS
MTS